12.5

Low Pressure Prevention Control (Gas Leakage Detection)

Control start conditions
For 5 minutes, the compressor continuously operates and outdoor total current is between 0.65A and 1.65A.
o
During Cooling and Soft Dry operation:
o
Indoor suction temperature – indoor piping temperature is below 4°C
Control contents
Compressor stops (and restart after 3 minutes).
o
If the conditions above happened 2 times within 20 minutes, the unit will:
o
Stop operation
Timer LED blinks and "F91" indicated.
12.6

Compressor Tank Temperature Rise Protection Control

Control start conditions
For 5 minutes, the compressor continuously operates and outdoor total current is between 0.65A and 1.65A.
o
During Cooling and Soft Dry operation:
o
Indoor suction temperature -indoor piping temperature is below 4°C.
Indoor temperature and outdoor temperature is 30±5°C.
Remote Control setting 16°C and Hi Fan Speed.
Control contents
Compressor stops (and restart after 3 minutes)
o
If the conditions above happened 2 times within 20 minutes, the unit will:
o
Stop operation
Timer LED blinks and "F91" indicated.
12.7

Low Frequency Protection Control 1

When the compressor operates at frequency lower than 24Hz continued for 20 minutes, the operation frequency
will be changed to 23Hz for 2 minutes.
12.8

Low Frequency Protection Control 2

When all below conditions comply, the compressor frequency will changed to lower frequency.
12.9

Outdoor Air Temperature Control

The compressor operating frequency is regulated in accordance to the outdoor air temperature as shown in the
diagram below.
This control will begin 1 minute after the compressor starts.
Compressor frequency will adjust based on outdoor air temperature.
Temperature, T, for:
Indoor intake air (°C)
Outdoor air (°C)
Indoor heat exchanger (°C)
Free
38°C
Limited Frequency
Outdoor air temperature
36
Cooling / Soft Dry
T < 15 or T ≥ 30
T < 16 or T ≥ 38
T < 30
37°C

Hide quick links: