10.2 Indoor Unit

10.2.1 How to Fix Installation Plate
The mounting wall is strong and solid enough to prevent if from the vibration.
Wall
Measuring
Tape
PS9***, PS12***
The centre of installation plate should be at more than
The distance from installation plate edge to ceiling should more than
From installation plate left edge to unit's left side is
From installation plate right edge to unit's right side is
B
: For left side piping, piping connection for liquid should be about
: For left side piping, piping connection for gas should be about
1
Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the wall, consider using anchor bolts.)
Always mount the installation plate horizontally by aligning the marking-off line with the thread and using
o
a level gauge.
2
Drill the piping plate hole with ø70mm hole-core drill.
Putting measuring tape at position as shown in the diagram above. The hole center is obtained by
o
measuring the distance namely 128mm for left and right hole respectively. Another method is
intersection point of arrow mark extension.
Drill the piping plate hole at either the right or left and the hole should be slightly slanted to the outdoor
o
side.
10.2.2 To Drill a Hole in the Wall and Install a Sleeve of Piping
1
Insert the piping sleeve to the hole.
2
Fix the busing to the sleeve.
3
Cut the sleeve until it extrudes about 15mm from the wall
When the wall is hollow, please be sure to use the sleeve for tube
ass'y to prevent dangers caused by mice biting the connecting
cable.
4
Finish by sealing the sleeve with putty or caulking compound at the
final stage.
More than 1
Screw
3
B
241.5mm
C
128mm
Model
485mm
Caution
Wall
More
than 2
128
Installation
6
plate
5
Dimension
1
2
3
82mm
165mm
1 mm at right and left of the wall.
2 .
3 .
4 .
6 from this line.
25
More than 1
Indoor unit
4
A
234.5mm
128mm
4
5
158mm
93mm
145mm
5 from this line.
Wall
Indoor
Sleeve for
tube ass'y
Ø 70 through hole
Wall
6
Outdoor
15 mm
Approx. 5 - 7 mm
Bushing for tube ass'y
Putty or caulking compound