2. How to connect it with the conventional DVR
- Connect the PoC repeater, RP101P, between the camera and DVR. And put additional
power adopter.
How to Set up Auto Focus
- Manual Focus Model : C1080PBL-IR18
To prevent out focus due to weather or environmental changes, please follow the bottom
instruction.
1) Press [SET] on the OSD remote controller and select "FOCUS ADJ" to enable "Adjust
Focusing" mode.
2) Use the lens' lever to adjust zoom and focus.
3) End the "Adjust Focusing" mode by pressing the [SET] on the OSD remote controller.
- Auto Focus Model : C1080PBL-IR18-AF / C1080PBL-IR48-AF
1) Press [SET] on the OSD remote controller and select "FOCUS ADJ" to enable "Adjust
Focusing" mode.
2) Hit "MANUAL", go into "Manual Focusing mode".
3) Hit "Tele" or "Wide" button to adjust.
4) Press [SET] on the OSD remote controller and to end Manual Focusing Mode.
5) Select "CORRECT AF" and hit [SET] to run "Auto Focusing function".
<Note>
1)
When
adjusting
automatically run "Adjust Focusing function".
How to use OSD remote controller
1. CVBS output
- Connect CCTV monitor to OSD remote controller's CVBS outport to check the image.
(SD quality)
- When images stop coming out, press any button on the OSD remote controller to see