Elation PLATINUM FLX User Manual page 38

Hide thumbs Also See for PLATINUM FLX:
Table of Contents

Advertisement

w w w . e l a t i o n l i g h t i n g . c o m
ELATION© PLATINUM FLX™
E R R O R
C O D E S
Specifications and features are subject to change without any prior written notice.
ERROR CODE
DESCRIPTION
The Flow Control movement is not located in the default position after
the reset. This message will appear after the reset of the fixture reset if
Flow Control Er
the magnetic-indexing circuit malfunctions (sensor failed or magnet is
missing) or there is a stepper motor failure (defective motor or
defective motor IC drive on main PCB).
The LightSource movement is not located in the default position after
the reset. This message will appear after the reset of the fixture reset if
LightSource Er
the magnetic-indexing circuit malfunctions (sensor failed or magnet is
missing) or there is a stepper motor failure (defective motor or
defective motor IC drive on main PCB).
The LightPipe movement is not located in the default position after the
reset. This message will appear after the reset of the fixture reset if the
LightPipe Er
magnetic-indexing circuit malfunctions (sensor failed or magnet is
missing) or there is a stepper motor failure (defective motor or
defective motor IC drive on main PCB).