ERROR CODE
The PAN movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a motor
PAN Er
failure (defective motor or a defective motor IC drive on the main PCB).
This error may also be displayed if the head/yoke was blocked during a
reset function.
The TILT movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing
TILT Er
circuit malfunctions (sensor failed or magnet is missing) or there is a motor
failure (defective motor or defective motor IC drive on main PCB). This error
may also be displayed if the head was blocked during a reset function.
The Cyan Color movement is not located in the default position after the
reset. This message will appear after a fixture reset if the gobo wheel's
Cyan Wheel Er
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing)
or there is a stepper motor failure (defective motor or defective motor IC
drive on main PCB).
The Magenta Color movement is not located in the default position after
the reset. This message will appear after a fixture reset if the
Magenta Wheel Er
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing)
or there is a stepper motor failure (defective motor or defective motor IC
drive on main PCB).
The Yellow Color movement is not located in the default position after the
reset. This message will appear after the reset of the fixture reset if the
Yellow Wheel Er
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing)
or there is a stepper motor failure (defective motor or defective motor IC
drive on main PCB).
The CTO Wheel is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the
CTO Wheel Er
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing)
or there is a stepper motor failure (defective motor or defective motor IC
drive on main PCB).
The Color Wheel is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the
Color Wheel Er
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing)
or there is a stepper motor failure (defective motor or defective motor IC
drive on main PCB).
The Gobo Wheel 1 movement is not located in the default position after
the reset. This message will appear after a fixture reset if the
Gobo Wheel 1 Er
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing)
or there is a stepper motor failure (defective motor or defective motor IC
drive on main PCB).