ERROR CODE
The Gobo Rot.1 movement is not located in the default position
after the reset. This message will appear after a fixture reset if the
Gobo Rot.1 Er
gobo wheel's magnetic-indexing circuit malfunctions (sensor failed
or magnet is missing) or there is a stepper motor failure (defective
motor or defective motor IC drive on main PCB).
The Gobo Wheel 2 movement is not located in the default position
after the reset. This message will appear after a fixture reset if the
Gobo Wheel 2 Er
magnetic-indexing circuit malfunctions (sensor failed or magnet is
missing) or there is a stepper motor failure (defective motor or
defective motor IC drive on main PCB).
The Prism1 movement is not located in the default position after the
reset.
This message will appear after the reset of the fixture reset if the
Prism1 Er
magnetic-indexing circuit malfunctions (sensor failed or magnet is
missing) or there is a stepper motor failure (defective motor or
defective motor IC drive on main PCB).
The Prism Rot.1 movement is not located in the default position after
the reset. This message will appear after a fixture reset if the gobo
Prism Rot.1 Er
wheel's magnetic-indexing circuit malfunctions (sensor failed or
magnet is missing) or there is a stepper motor failure (defective
motor or defective motor IC drive on main PCB).
The Prism2 movement is not located in the default position after the
reset.
This message will appear after the reset of the fixture reset if the
Prism2 Er
magnetic-indexing circuit malfunctions (sensor failed or magnet is
missing) or there is a stepper motor failure (defective motor or
defective motor IC drive on main PCB).
The Prism Rot.2 movement is not located in the default position after
the reset. This message will appear after a fixture reset if the gobo
Prism Rot.2 Er
wheel's magnetic-indexing circuit malfunctions (sensor failed or
magnet is missing) or there is a stepper motor failure (defective
motor or defective motor IC drive on main PCB).
The Focus movement is not located in the default position after the
reset.
This message will appear after the reset of the fixture reset if the
Focus Er
magnetic-indexing circuit malfunctions (sensor failed or magnet is
missing) or there is a stepper motor failure (defective motor or
defective motor IC drive on main PCB).
The Zoom movement is not located in the default position after the
reset.
This message will appear after the reset of the fixture reset if the
Zoom Er
magnetic-indexing circuit malfunctions (sensor failed or magnet is
missing) or there is a stepper motor failure (defective motor or
defective motor IC drive on main PCB).