Maintenance
Actuator Scrub Deck Removal/
Replacement
FOR SAFETY: Before leaving or servicing machine,
stop on a level surface. Turn off machine.
1. Lower scrub deck. Remove the front cover and
raise recovery tank.
2. Disconnect electrical connector.
3. Remove the clevis pin retaining the bottom of the
actuator.
4. Remove the clevis pin retaining the top of the
actuator.
5. Reverse for re-installation.
32
Scrub Deck Actuator Adjustment
The actuator will need to be adjusted when replaced.
To adjust the actuator:
1. While holding actuator barrel to prevent it from
spinning, apply power to the actuator such that it is
fully extended. Positive power to white wire, and
negative/ground to black. Limit switch within
actuator will stop it.
2. With actuator fully extended, attach to the top
bracket.
3. At the bottom mount align the mounting hole with
the center of the slot, turn the barrel in or out
enough to align connection to bracket.
4. Connect actuator electrical plug.
5. Check travel of actuator during operation.