Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
MAGNETRON
Refer to page 4-10 for the procedure for servic-
ing the magnetron.
1.
Unplug microwave oven or disconnect
power.
2.
Discharge the high voltage capacitor
terminals with a 20,000
chassis ground.
3.
Disconnect the wire connectors from the
filament terminals.
4.
Set the ohmmeter to the R x 1 scale.
5.
Touch the ohmmeter test leads to the
filament terminals. The meter should indi-
cate less than 1 Ω.
6.
Touch one ohmmeter test lead to the
chassis, and the other test lead to each of
the filament terminals. The meter should
indicate infinity (∞).