7) CAREFULLY position the FILTER TUB COVER on the OPEN end of the Filter Tub with the SLOT on the cover seated around the
Standpipe Handle Docking Assembly. Then, SECURE the cover to the standpipe assembly by locking the latch on the cover.
8) Position the ASSEMBLED Filter Tub in front of the FILTER TUB GUIDES beneath the fryer; then CAREFULLY and SLOWLY
insert the Filter Tub into the fryer using Standpipe Docking Handle Assy until the MALE In Line Plug on the Standpipe Docking
Handle Assembly seats in the FEMALE Bulkhead Coupling adjacent to the Drain Valve Assembly.
WARNING!!! TO ASSURE PRODUCING A QUALITY PRODUCT WHILE PROLONGING THE LIFE EXPECTANCY OF THE FRYER, ENSURE
FILTERING, BOIL-OUT AND CLEANING INSTRUCTIONS ARE STRICTLY ADHERED TO.
d. CLEANING THE FILTER TUB AFTER CLOSING
1) "Micro Mesh" Stainless Steel Filter Screen:
Repeat DAILY steps 1 c ; then, THOROUGHLY clean the Filter Assembly as follows:
a) THOROUGHLY flush any remaining sediment from both sides of the filter screen with HOT WATER.
b) Grasp the FINGER LOOP on FRAME A and adjacent FINGER LOOP on FRAME B, EVENLY pull the frames apart;
then HINGE FRAME A to remove it from the FILTER SCREENS FIRST.
c) Grasp the FINGER LOOP on the straight side of FRAME B; then HINGE it to remove FRAME B from the FILTER
SCREENS.
d) Separate the UPPER FILTER SCREEN and BAFFLE from the LOWER FILTER SCREEN.
e) CAREFULLY clean the two frames, screens and baffle in the 3 compartment sink with hot water and allow these
items to air dry. DO NOT USE SOAP. If necessary the channels in each frame can be cleaned with the edge of a
scotchbrite pad.
f)
Insert the SUCTION FITTING on the BAFFLE in the hole of the UPPER FILTER SCREEN; then place these items
on top of the LOWER FILTER SCREEN.
g) ENSURE all sides of the FILTER SCREEN assembly are aligned, place the PIN end of FRAME A on the FILTER
SCREENS, place the CHANNEL on the frame adjacent to the PIN end over the FILTER SCREENS; then HINGE the
frame so the edge of the FILTER SCREENS are inserted in the other CHANNEL of FRAME A.
h) Place the PIN end of FRAME B on the FILTER SCREENS so the PIN is seated in the CHANNEL of FRAME A near
the FINGER LOOP, place the CHANNEL on the frame adjacent to the PIN end over the edge of the FILTER
SCREENS; then HINGE the frame so the edge of the FILTER SCREENS are inserted in the other CHANNEL of
FRAME B and the PIN on FRAME B is seated in the CHANNEL of FRAME A.
Adjust FRAME A and B so other PINS are properly seated in the CHANNEL of the opposite frame; then CAREFULLY
i)
connect the KNURL KNOB and STANDPIPE/DOCKING ASSEMBLY to the SUCTION FITTING on the FILTER
SCREEN assembly. DO NOT OVERTIGHTEN!!!
2) "Magnepad" Envelope Filter:
Remove and discard the USED Filter Pad Envelope. CAREFULLY clean the Baffle Assembly and Clip/Stand-pipe assem-
bly in a 3 compartment sink with HOT water and allow these items to air dry. DO NOT USE SOAP!! Reassemble the
Magnepad Envelope Filter using a NEW Magnesol Impregnated Filter Pad Envelope as follows:
a) Insert the BAFFLE into the FILTER PAD ENVELOPE, when properly inserted the SUCTION FITTING will
protude through the hole in the pad.
b) Fold the FLAP over (in the direction of the hole) securing the Baffle inside the FILTER PAD ENVELOPE.
c) CAREFULLY align the CLIP & STANDPIPE ASSEMBLY so that the clip can secure the FLAP and the
envelope and the STANDPIPE will align over the SUCTION FITTING protruding through the envelope.
d) Tighten the knurled NUT on the STANDPIPE to the SUCTION FITTING protruding through the envelope.
e) Repeat DAILY steps 1 a through 1 d .

2. WEEKLY

a.
Perform daily cleaning steps 1a through 1c.
b.
Clean the Filter Assembly as follows:
1)
"Micro-Mesh" stainless steel filter screen:
a) Disassemble the filter accordingly to DAILY steps 1 c 4) and clean the two (2) frames as described in step 1 c 4) a) (5)
b) Place the upper and lower FILTER SCREENS in the fryer with BOIL-OUT SOLUTION for cleaning. DO NOT
PLACE THE BAFFLE OR STANDPIPE IN THIS SOLUTION!!! BOIL-OUT the fryer vat according to instructions
contained in the cleaning manual provided by your chemical supplier.
c) After the filter screens have been cleaned in the Boil-Out Solution, ENSURE they are THOROUGHLY sprayed with
a solution of 1 PART vinegar to 25 PARTS of water to NEUTRALIZE the boil-out solution, then allow the screens
to air dry. NOTE: any residue of boil-out solution on the filter screens could cause the rapid break-down of the
shortening.