Test Start-Up - ULTRAFRYER F-P20-18 Operation Instructions Manual

Gas fryer
Table of Contents

Advertisement

F.

TEST START-UP :

TO TEST OPERATE an Ultrafryer Gas Fryer equipped with a Default-to-Manual-Restart (DTMR) control:
a.
1) Ensure the fryer's Toggle ON/OFF Switch is in the OFF position.
2) Fill the fryer vat with hot or cold water to the middle of the "E" in the word LEVEL of the applicable shortening level
mark on the rear of the vat.
3) Turn the MANUAL gas valve to the OFF position and wait FIVE (5) minutes for any accumulated gas to disperse.
4) ENSURE the MAIN gas shut-off valve is in the ON position, and that the Vent Hood EXHAUST FAN is ON.
5) Turn the MANUAL GAS VALVE to the ON position.
6) Perform the following steps, in the order listed:
ITEM
ENSURE the drain valve is in the CLOSED
1
position and that water is at the proper level; then
turn the Toggle ON/OFF switch to the ON position.
CAUTION: PRIOR TO PROCEEDING TO STEP 2 VISUALLY CHECK THAT THE HEAT MECHANISM IS
COVERED WITH AT LEAST 2" (51 mm) OF WATER.
2
Depress, then release the momentary START button
CAUTION: PRIOR TO PROCEEDING TO STEP 3, VISUALLY CHECK THAT THE WATER
COMPLETELY COVERS THE HEAT MECHANISM.
When heated and water is above the heat tubes;
3
Depress, then release the momentary EXIT MELT
button.
When the water begins to boil, turn the fryer OFF,
4
and after the water has COOLED drain the water
into a floor drain.
��� ������� ����
���� �����
�� �����
����
�����
������
ACTION
Page 16 of 56
����� ����
���� ����
���� ����
������
DTMR CONDITION
A. AMBER power lamp will LIGHT.
B. BLUE READY TO START lamp will LIGHT.
A. RED STARTED lamp and AMBER MELT
MODE lamp will light.
B. BLUE READY TO START lamp will turn OFF.
C. A MELT CYCLE TIMING MODULE in the
Default-To-Melt electrical circuit will begin cycling
the fryer heat mechanism ON for ten (12) seconds
and OFF for 28 seconds to safely heat the water.
A. AMBER MELT MODE lamp will turn OFF and
the RED STARTED lamp will remain lit.
B. The MELT CYCLE TIMING MODULE in the
Default-To-Melt circuit will switch to the FULL ON
position, allowing the Electronic Thermostat to heat
water.
30A168

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

F-p20-20

Table of Contents