Wire Cage; Remove Wire Cage/Bowl Guard; Install Wire Cage/Bowl Guard; Cleaning - Berkel FMS30 Owner's Manual

Hide thumbs Also See for FMS30:
Table of Contents

Advertisement

BOWL GUARD / WIRE CAGE
Wire cage must be in position and closed in order to mix. If wire cage is opened during the mixing, mixer will stop.
REMOVE BOWL GUARD / WIRE CAGE
Lower the bowl support and remove agitator before removing bowl guard/wire cage. Hold wire cage with both
pull
hands and
downward gently to release from retainer (Fig. 5).
INSTALL BOWL GUARD / WIRE CAGE
Hold wire cage with both hands and gently push upward until bowl guard/wire cage is latched on the retainer and
rotated
can be
freely (Fig. 5).

CLEANING

Disconnect electrical power before beginning any cleaning procedures.
The mixer should be thoroughly cleaned daily.
Bowls and agitators should be removed from the mixer and cleaned in a sink.
DO NOT use a hose to clean the mixer — it should be washed with a clean damp cloth.
Clean the bowl guard/wire cage by wiping with a cloth or sponge and warm soapy water.
– 8 –
FMS30 & FMS40 Owner/Operator Manual