Shutdown and Cleaning
Power Flushing After Spraying Water-Base Paint
For short shutdown periods (breaks on the job), leave
suction tube and prime tube in paint, and relieve the
pressure by turning the Spray/Prime valve to PRIME
(see WARNINGS sheet). For extended shutdown
periods, clean sprayer by flushing as instructed in this
section.
See Pail Flushing in the enclosed Operating Instructions for flushing after
spraying non-water/solvent coatings.
Fluid Injection Hazard
See WARNINGS sheet.
1. Turn power
2. Place suction tube
switch OFF.
and prime tube in
empty waste pail.
4. Unscrew tip & guard from gun, and place them in waste pail.
WASTE
10
PRIME
(to relieve pressure)
3. Turn Spray/Prime
valve to PRIME to
relieve pressure.
PRIME
WASTE
Shutdown and Cleaning
Power Flushing After Spraying Water-Base Paint
5. Screw Power Flush
6. Turn on water, and
attachment onto
garden hose, and
open Power Flush
attachment.
open
closed
Power Flush
attachment
garden hose
8. Unscrew inlet screen from
suction tube, and place it in
waste pail.
inlet screen
WASTE
7. Turn lever to
rinse paint off suction
close Power
tube, prime tube, and
Flush
inlet screen.
attachment.
close
WASTE
9. Connect garden hose to suction
tube with Power Flush attachment.
Leave prime tube in waste pail.
Power Flush
attachment
garden hose
WASTE
11