40069 Zola Predosa (BO) - ITALY
The connection to the mains, to be carried out by qualified personnel, and the safety systems must
comply with local rules and laws.
Before connecting the unit to the electric power, verify that the voltage and the frequency available on the
mains correspond to the data reported on the data plate of the dryer. In terms of voltage, a ±5% tolerance is
allowed.
The dryers RD come with an electric box for the connection to the mains.
The mains socket must be provided with a mains magneto-thermal differential breaker (I∆n=0.03A),
adjusted on the basis of the consumption of the dryer (see the nominal values on the data plate of the dryer).
The cross section of the power supply cables must comply with the consumption of the dryer, while keeping
into account also the ambient temperature, the conditions of the mains installation, the length of the cables,
and the requirements enforced by the local Power Provider.
Connect to a properly grounded outlet. Improper connection of the equipment-grounding
conductor can result in risk of electric shock.
Do not use adapters on the plug receptacle - if it does not fit the outlet, have a proper outlet
installed by a qualified electrician.
The condensate is discharge at the system pressure.
Drain line should be secured
Never point the condensate drain line towards anybody.
The dryer comes with a flexible plastic drain tube.
The condensate drain occurs through a solenoid valve protected with a mechanical strainer.
The condensate coming from the separator is previously filtered, then discharged.
The solenoid valve coil is operated by electronic instrument (dryer controller).
If an electronic drainer is installed, the intervention times are determined by the internal capacitive sensor
(see specific paragraph).
The drainers cannot be connected to pressurized systems.
Don't dispose the condensate in the environment.
The condensate collected in the dryer contains oil particles released in the air by the compressor.
Dispose the condensate in compliance with the local rules.
We suggest to install a water-oil separator where to convey all the condensate drain coming from
compressors, dryers, tanks, filters, etc.
Verify that the operating parameters match with the nominal values stated on the data nameplate of
the dryer (voltage, frequency, air pressure, air temperature, ambient temperature, etc.).
This dryer has been thoroughly tested, packaged and inspected prior to shipment. Nevertheless, the unit
could be damaged during transportation, check the integrity of the dryer during initial start-up and monitor
operation during the first hours of operation
Qualified personnel must perform the initial start-up.
When installing and operating this equipment, comply with all National Electrical Code and any
applicable federal, state and local codes.
Who is operating the unit is responsible for the proper and safe operation of the dryer.
Never operate equipment with panels removed.

2.8 ELECTRICAL CONNECTIONS