Correction Factors - Fini RD 185-810 User Manual

Refrigerated
Table of Contents

Advertisement

40069 Zola Predosa (BO) - ITALY
Correction factor for operating pressure changes :
Inlet air pressure
Factor (F1)
Correction factor for ambient temperature changes (Air-Cooled):
Ambient temperature
Factor (F2)
Correction factor for inlet air temperature changes:
Air temperature
Factor (F3)
Correction factor for DewPoint changes:
DewPoint
Factor (F4)
How to find the air flow capacity:
Air flow
Nominal
Factor
=
X
capacity
duty
(F1)
Example:
An RD 185 has a nominal duty of 18500
l/min. What is the maximum allowable flow
through the dryer under the following operating
conditions:
Inlet air pressure = 8 barg
Ambient temperature = 45° C
Inlet air temperature = 50° C
Pressure DewPoint = 10° C
Each item of data has a corresponding numerical
factor which multiplied by the design air flow is as
follows:
Air flow
18500
1.06
=
x
capacity
= 13206 l/min → This is the maximum
flow rate that the dryer can accept under these
operating conditions.

2.5 CORRECTION FACTORS

barg
4
0.77
ºC
< 25
1.00
ºC
< 30
1.20
ºC
3
1.00
Factor
Factor
Factor
X
X
X
(F2)
(F3)
(F4)
0.80
0.61
1.38
x
x
x
info@finicompressors.it
5
7
0.85
1.00
1.06
30
35
0.98
0.95
35
40
1.00
0.85
5
1.09
How to select a suitable dryer for a given duty:
Minimum
Design
=
Std. air
air flow
flow rate
Example:
The procedure here is to list the operating
conditions
and
corresponding numerical factors:
Design air flow = 16200 l/min
Inlet air pressure = 8 barg
Ambient temperature = 45° C
Inlet air temperature = 50° C
Pressure DewPoint = 10° C
In order to select the correct dryer model the
required flow rate is to be divided by the correction
factors relating to above mentioned parameters:
Minimum
16200
=
flow rate
= 22693 l/min → Therefore the model
suitable for the conditions above is RD 250 (25000
l/min - nominal duty).
8
10
12
1.15
1.21
40
0.90
45
50
0.75
0.61
7
1.18
Factor
Factor
Factor
÷
÷
÷
(F1)
(F2)
(F3)
then
to
locate
1.06
0.80
0.61
÷
÷
÷
- EN -
14
1.25
45
0.80
55
0.49
10
1.38
Factor
÷
(F4)
the
1.38
÷