Dunkirk EXCELSIOR EXB4075 Installation, Operation & Maintenance Manual page 51

High efficiency oil fired hot water boiler
Hide thumbs Also See for EXCELSIOR EXB4075:
Table of Contents

Advertisement

Table 16 - Riello 40BF (DIRECT VENT) Preliminary Burner Settings
Burner settings provided are for initial startup only. Final adjustments must be made using combustion test
instruments.
Table 16: RIELLO 40BF DIRECT VENT PRELIMINARY BURNER SETTINGS
Head
Boiler Model
Type
4075
Reverse
4095
Standard
4110
Standard
5100
Standard
5115
Standard
5135
Standard
6130
Standard
Timings
Pre-purge
12 seconds
Post-Purge
45 seconds
17 - OIL BURNER, NOZZLE, & AIR SETTINGS
Inser-
Firing
Com-
tion
Rate
bustion
Depth
[GPH]
Liner
2.75"
0.75
Oval
1.75"
0.95
Oval
1.75"
1.10
Oval
2.75"
1.00
None
1.75"
1.15
None
1.75"
1.35
None
2.75"
1.30
V6
Riello
Boiler
Oil
Model
Burner
Model
4075
40BF3
4095
40BF5
4110
40BF5
5100
40BF5
5115
40BF5
5135
40BF5
6130
40BF5
Pump
Nozzle
Nozzle
Pres-
Mfr.
Type
sure
[PSI]
Delavan 0.65x60W
150
Delavan
0.75x90B
175
Delavan
1.00x90B
125
Delavan
0.75x60B
175
Delavan
1.00x80B
130
Delavan
1.20x80B
125
Delavan
1.00x45B
175
ECR Oil Burner
Part Number
240007528
240009407
240009408
240007529
240009409
240009410
240007530
51
Pressure
Head
Air
Switch
Setting
Setting
Setpoint
3
5.0
0.25" WC
1
4.0
0.25" WC
2
5.0
0.25" WC
1
5.0
0.80" WC
2
5.8
0.80" WC
4
5.8
0.80" WC
2
8.0
0.90" WC
Rated
AFUE
Efficiency
[%]
86.0
85.0
84.0
86.5
85.0
84.0
86.5

Advertisement

Table of Contents
loading

Table of Contents