I. Optional Blower
The GFK-160A Blower has been designed to circulate room
air through the appliance to enhance heat output.
The GFK-160A blower system operates on 120 VAC, 60 Hz
power. This is available through a receptacle in the factory
installed junction box. The junction box is mounted in the
bottom of the appliance behind the access panel. A variable
speed control is provided with the blower system to provide
quiet forced air flow at the desired speeds. A temperature
sensor switch, which automatically turns the blower ON/
OFF, is also provided with this kit.
Compare contents of carton with the actual parts received.
If any parts are missing or damaged, contact your dealer
before starting installation. Do not install a damaged blower
kit. See Figure 8.21.
BLOWER
CONTROL
KNOB
GROUND
CLIP
CONTROL
NUT
SPEED
CONTROL
Figure 8.21
Installation precautions
The GFK-160A Blower kit is tested and safe when
installed in accordance with this installation manual. It is
your responsibility to read all instructions before starting
installation and to follow these instructions carefully during
installation to assure maximum benefit from, and safe
operation, of the blower.
This blower is carefully engineered and must be installed
only as specified. If you modify it or any of its components,
you may cause a fire hazard and will void the WARRANTY.
In addition, such action may void the coverage provided by
the owner's home insurance.
!
All wiring should be done by a qualified electrician and shall be
in compliance with local codes and with the National Electric
Code ANSI/NFPA NO. 70-current (in the United States), or with
the current CSA C22.1 Canadian Electric Code (in Canada).
37
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 R14 • 11/14
WING
NUT
TEMP.
SENSOR
SWITCH
CAUTION
!
Shock Risk
Explosion Risk
Do NOT wire 110-120 VAC to gas control valve.
Do NOT wire 110-120 VAC to wall switch.
• Incorrect wiring will damage millivolt valves.
• Incorrect wiring will override IPI safety lockout and
may cause explosion.
Disconnect all electrical power. Remove the front door
assembly by lifting off of appliance. Remove the lower
access door. See Figure 8.22.
Figure 8.22
Attach enclosed wires to the temperature sensor switch/
bracket assembly. The blue wire attaches to the rear of the
bracket and one of the black wires from the variable speed
control attaches closest to the prepunched screw hole. See
Figure 8.23.
Black Wires
Figure 8.23
Feed the blue wire and other black wire from the variable
speed control behind the gas valve assembly. Insert the
wires into the slots indicated in Figure 8.28.
WARNING
Blue Wires