BPA60
Power Amplifier
Installation & Use Manual
Technical
Specifications
Thermal Emissions (full power):
Auxiliary Receptacle (not switched):
Rated Output Power:
Total Harmonic Distortion:
Frequency Response:
Input Sensitivity:
Hum and Noise:
Output Loads:
Output Regulation:
Input Impedances:
Lo-cut Filter:
Controls and Indicators:
Power Consumption:
Overload Protection:
Dimensions:
Finish:
Weight:
Accessories:
60 watts
Less than 2% from 50 Hz to 15 kHz
-2 dB, 20 Hz to 20 kHz
High-impedance, 300mV; low-impedance balanced (with optional
transformer), 75mV
85 dB below rated output
8-ohm/25V, 16-ohm, 25V CT, 70V
Better than 2 dB from no load to full load
High-impedance, 50k ohms unbalanced; low-impedance, 600 ohms,
balanced (with optional transformer)
-10 dB at 100 Hz (switch-selectable)
Front Panel — Illuminated on/off power switch
Rear Panel — Input level control, circuit breaker reset, lo-cut filter switch
120V AC, 60 Hz, 180W at full rated output
204.9 BTU/hr.
Transient protection diodes, electrical circuit breaker,
thermostat
Three-wire grounded*, 300W maximum, 2.5A (internally fused)
15-1/4"W x 3-1/2"H x 8"D
Black
19 lbs.
Model TL600, 600-ohm line-matching transformer;
Model TL100, 1:1 ratio transformer
Model RPK53 rack panel brackets
*This receptacle will be grounded only if the power amplifier has been grounded properly.
Specifications subject to change without notice.
© 2009 Bogen Communications, Inc.
All rights reserved.
54-5810-05B 1007