Thermal Emissions (full power):
Auxiliary Receptacle (not switched):
Rated Output Power:
Total Harmonic Distortion:
Frequency Response:
Input Sensitivity:
Hum and Noise:
Output Loads:
Output Regulation:
Input Impedances:
Lo-cut Filter:
Controls and Indicators:
Power Consumption:
Overload Protection:
Dimensions:
Finish:
Weight:
Accessories:
60 watts
Less than 2% from 50 Hz to 15 kHz
-2 dB, 20 Hz to 20 kHz
High-impedance, 300mV; low-impedance balanced (with optional
transformer), 75mV
85 dB below rated output
8-ohm/25V, 16-ohm, 25V CT, 70V
Better than 2 dB from no load to full load
High-impedance, 50k ohms unbalanced; low-impedance, 600 ohms,
balanced (with optional transformer)
-10 dB at 100 Hz (switch-selectable)
Front Panel — Illuminated on/off power switch
Rear Panel — Input level control, circuit breaker reset, lo-cut filter switch
120V AC, 60 Hz, 180W at full rated output
204.9 BTU/hr.
Transient protection diodes, electrical circuit breaker,
thermostat
Three-wire grounded*, 300W maximum, 2.5A (internally fused)
15-1/4"W x 3-1/2"H x 8"D
Black
19 lbs.
Model TL600, 600-ohm line-matching transformer;
Model TL100, 1:1 ratio transformer
Model RPK53 rack panel brackets
*This receptacle will be grounded only if the power amplifier has been grounded properly.
Specifications subject to change without notice.
© 2009 Bogen Communications, Inc.
All rights reserved.
54-5810-05B 1007

Advertisement

loading
Need help?

Need help?

Do you have a question about the BPA60 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bogen BPA60

  • Page 1: Power Amplifier

    Model TL100, 1:1 ratio transformer Model RPK53 rack panel brackets *This receptacle will be grounded only if the power amplifier has been grounded properly. Specifications subject to change without notice. © 2009 Bogen Communications, Inc. All rights reserved. 54-5810-05B 1007...
  • Page 2: Important Safety Instructions

    Description The Bogen BPA60 Power Amplifier has been designed to ful- An AC circuit breaker and transient protection diodes prevent dam- fill the power amplification requirements of professional and com- age due to overloads.
  • Page 3: Output Connections

    It is recommended that the amplifier be installed on the bottom of a The BPA60 may be driven from an amplifier that provides a 25V rack or above any equipment that does not produce heat.
  • Page 4 Limited Warranty; Exclusion of Certain Damages The Bogen BPA60 Amplifier is warranted to be free from defects in material and workmanship for two (2) years from the date of sale to the original purchaser. Any part of the product covered by this warranty that, with normal installation and use, becomes defective (as confirmed by Bogen upon inspection) during the applicable warranty period, will be repaired or replaced by Bogen, at Bogenʼs...