Environmental Specifications

Environmental Specifications
Table A-2
Table A-2
Description
Temperature, operating
Temperature, nonoperating
Humidity, operating
Humidity, nonoperating
Altitude, operating
Derated 1ºC for each 305 m
Altitude, nonoperating
Acoustic noise, operating

Power Specifications

Table A-3
Table A-3
Description
Class
AC input voltage
AC input frequency
AC line current (steady state)
AC line inrush current
Maximum output power for each power
supply
Power supply output voltage
Rated output load
You can get more specific power information for your exact server configuration by using the Cisco UCS
Power Calculator:
http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/
Cisco UCS C3160 Rack Server Installation and Service Guide
A-2
lists the environmental specifications for the server.
Environmental Specifications
lists the specifications for each 1050 W power supply (Cisco part number UCSC-C3X60-PSU).
1050 W Power Supply Specifications
Appendix A
Specification
5ºC to 35ºC (41ºF to 95ºF)
–40ºC to 65ºC (–40ºF to 149ºF)
10% to 90% non-condensing
5% to 93% non-condensing
0 m to 3048 m (0 ft to 10,000 ft)
0 m to 12,192 m (0 ft to 40,000 ft)
LWAd 5.4 Bel
LpAm 38 dBA
Specification
RSP2
100 to 240 VAC nominal (Range: 90 to 264 VAC)
47 to 63 Hz nominal (Range: 47 to 63 Hz)
12.5 A maximum at 100 VAC
6.0 A maximum at 208 VAC
15 A peak at 35ºC, 208 VAC
1050 W on main power
30 W on standby power
Main power: 12 VDC
Standby power: 12 VDC
Main power: 87.5 DC Amps (at 180-264 VAC),
66.67 DC Amps (at 90-180 VAC)
Standby power: 2.5 DC Amps