8
Connection
Siemens AG
Do not connect the power cable until all other connections have been
CAUTION
completed. Any unused wires should be trimmed and insulated.
Abb. 7
Connection
1
Monitor
2
Video
3
DVR/VCR
4
Power supply
5
RS-485 connection
6
Twisted-pair video output
7
Aut. switching between
colour and B/W /
Alarm input
8
Remote control
RS-232 connection,
PC configuration
MD output
BNC
BNC
BNC
A
Red
B
White
C
Blue
D
Green
E
Yellow
F
Brown
G
Grey
H
Black/White
I
Black
J
Orange
Pink
Light blue
Violet
Connection
+12 V DC / 24 V AC
- 12 V DC / 24 V AC
RS-485(-)
RS-485(+)
TP-A(+)
TP-B (-)
Ext. input
Ext. output
GND
Control
TxD
RxD
MD/FD off: 0 V, on: 3.3 V
17
04.2011