Keypad
Command
Entry
Description
68#
MODEL TYPE
69#
ID TRANSFER
70# & 71#
(NOT USED)
72#
AUDIO GAIN
ADJUST
73#
RF POWER
LEVEL
ADJUST
6/29/98
Table 3: Test Commands For Manual Test Mode
Status
Display
Read model type.
Display three radio model bytes: hardware (model), flex
(type), and factory.
Reserved for Identity Transfer Procedure.
APC GAIN
STEP #
PARAMETER
00
Max. deviation
Chan. 991-1023, 1-100
01
Max. deviation
Chan. 101-322
02
Max. deviation
Chan. 323-544
03
Max. deviation
Chan. 545-766
04
Max. deviation
Chan. 767-866
05
VSP audio path deviation
06
Mic. audio deviation
07
DTMF deviation
08
Data deviation
09
SAT deviation
0A
Discriminator audio gain
0B
DSAT Phase Mod adjust
0C
Headset Mic Path adjust
STEP #
POWER LEVEL
00
Power Step 0
01
Power Step 1 (Step 2.5)
02
Power Step 2
03
Power Step 3
04
Power Step 4
05
Power Step 5
06
Power Step 6
07
Power Step 7
08-0B
Do Not Adjust
15
Manual Test Mode
Result
RANGE
(HEX)
0-7
0-7
0-7
0-7
0-7
0-F
0-F
0-3
0-3
0-3
0-F
0-7
0-F
RANGE
(HEX)
00-FF
00-FF
00-FF
00-FF
00-FF
00-FF
00-FF
00-FF