Keypad
Command
Entry
Description
34#
DTMFOFF
35A#
AUDIO-PATH
36#
(NOT USED)
37#
(NOT USED)
38#
SND-ESN
39#
RCVSU
6/29/98
Table 3: Test Commands For Manual Test Mode
Status
Display
AA
BB
De-activate DTMF tone.
Change the audio path to A, where A =:
0 = Hands free (selects input signal AUDIO IN @ J3-
pin 8 and outputs audio signal AUDIO OUT/ON-
OFF @ J3-pin 7; internal speaker and microphone
are muted.)
1 = Speaker (normal audio path; selects internal mic
and outputs audio @ AUDIO OUT/ON-OFF @ J3-
pin 7; internal speaker is muted.)
2 = Alert (activates the alert transducer for as long as
the # key is pressed. To prevent overstressing the
alert transducer., DO NOT hold the # key down for
extended periods.)
3 = Handset (selects the internal mic and speaker.)
4 = Mute (all audio paths and supplies are off.)
5 = External Radio (routes the internal mic audio
directly to AUDIO OUT/ON-OFF @ J3-pin 7, and
routes audio input at AUDIO IN @ J3-pin 8 directly
to the earpiece speaker.)
6 = External Handset (selects input audio at AUDIO IN
@ J3-pin 8, and outputs audio at AUDIO OUT/ON-
OFF @ J3-pin 7; internal speaker and mic are
muted, and sidetone is turned on.)
7 = Handset Answering Machine (audio from internal
microphone is routed to Answering Machine
input.)
8 = External Accessory Answering Machine Record
(audio from AUDIO IN @ J3-pin 8 is routed to
Answering Machine input.)
9 = External Headset (selects input audio at AUDIO IN
and outputs audio at AUDIO OUT/ON-OFF to
headset connector; internal speaker and mic are
muted, and sidetone is turned on.)
AA = Address; BB = Data
Send the ESN to the display. The byte address is
displayed in the right side and the contents of that
address will be displayed in hex. Use the * key to step
through the addresses.
Receive one control channel word. When the word is
received it is displayed in hex. This command will be
complete when a control channel word is received or
when the # key is entered to abort the command.