W Audio ZENITH 3000 Operation Manual

W Audio ZENITH 3000 Operation Manual

Audio power amplifiers zenith series

Advertisement

Quick Links

OPERATION MANUAL

This manual does not include all of the details of design, production, or variations of the equipment. Nor does it cover every
possible situation which may arise during installation, operation or maintenance.
The information provided in this manual was deemed accurate as of the publication date.
www.prolight.co.uk
PROTECT
PROTECT
CLIP
CLIP
ZENITH 3000
SIGNAL
SIGNAL
ACTIVE
ACTIVE
I
O
-
-
dB
0
dB
0
CH A
POWER
CH B
ZENITH SERIES

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZENITH 3000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for W Audio ZENITH 3000

  • Page 1: Operation Manual

    OPERATION MANUAL PROTECT PROTECT CLIP CLIP ZENITH 3000 SIGNAL SIGNAL ACTIVE ACTIVE CH A POWER CH B ZENITH SERIES This manual does not include all of the details of design, production, or variations of the equipment. Nor does it cover every possible situation which may arise during installation, operation or maintenance.
  • Page 2: Important Safety Instructions

    Professional Power Amplifier Important Safety Instructions 1) Read these instructions. TO PREVENT ELECTRIC SHOCK DO NOT REM- 2) Keep these instructions. OVE TOP OR BOTTOM COVERS. NO USER SE- 3) Heed all warnings. RVICEABLE PARTS INSIDE. REFER SERVICING 4) Follow all instructions. TO QUALIFIED SERVICE PERSONNEL.
  • Page 3: Declaration Of Conformity

    Professional Power Amplifier CE Declaration of Conformity Equipment Type: Audio Power Amplifiers Model Names: ZENITH 3000,ZENITH2400,ZENITH1800 This product has been assessed against the following applicable Standards, EMC (89/336/EEC Electromagnetic compatibility): EN55013:2001 Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement...
  • Page 4: Table Of Contents

    Professional Power Amplifier Table of Contents 2.6.2 Parallel Mono Mode..............9 Important Safety Instructions ............2 2.6.3 Bridge-Mono Mode ............10 Declaration of Conformity ............3 2.6.4 Low Cut Mode..............10 1 Welcome .................5 2.6.5 Low Pass Mode..............10 1.1 Features ................5 2.6.6 limiter Mode..............10 1.2 How to Use This Manual ............5 2.7 Connect to AC Mains .............11 2 Setup ..................6 2.8 Startup Procedure ..............11...
  • Page 5: Welcome

    Professional Power Amplifier ZENITH 3000 PROTECT PROTECT CLIP CLIP 4-ohm Stereo 1600W ZENITH 3000 Zenith 3000 SIGNAL SIGNAL ACTIVE ACTIVE 8-ohm Stereo 1000W 8-ohm Bridge-Mono 3000W CH A POWER CH B *1KHz Power:refers to maximum average power in watts at 1KHz with 0.5% THD.
  • Page 6: Setup

    Output wiring cables Rack for mounting amplifier (or a stable surface for stacking) PROTECT PROTECT CLIP CLIP ZENITH 3000 SIGNAL SIGNAL WARNING: Before you start to set up your ACTIVE ACTIVE amplifier, make sure you read and observe the Important Safety Instructions found at the beginning of this manual.
  • Page 7: Choose Input Wire And Connectors

    Professional Power Amplifier 2 Setup 2.4 Choose Input Wire and Connectors wired, balanced line (two-conductor plus shield), 22-24 gauge cables and connectors. Depending upon which am- plifier input you choose, you should use either 3-pin male XLR connectors, or jack connectors for the amplifier inputs. Unbalanced line may also be used but may result in noise over long cable runs.
  • Page 8: Wire Your System

    SIGNAL - PIN 1- : GROUND 80Hz 125Hz LIFT GROUND LOW PASS -B GROUND stereo 21 000W ZENITH 3000 OUTPUT B ~2202 40V 16A 50/60Hz LINK B INPUT B stereo 21 600W SPEAKERS Figure 2.5 System Wiring, Stereo Mode page 8...
  • Page 9: Parallel Mono Mode

    SIGNAL - PIN 1- : GROUND 80Hz 125Hz LIFT GROUND LOW PASS -B GROUND stereo 21 000W ZENITH 3000 OUTPUT B ~2202 40V 16A 50/60Hz LINK B INPUT B stereo 21 600W SPEAKERS Figure 2.6 System Wiring, Parallel Mode Operation Manual...
  • Page 10: Bridge-Mono Mode

    LIFT GROUND LOW PASS -B GROUND Low Cut Filter cuts off signal frequency below 30/80Hz or 50Hz stereo 21 000W ZENITH 3000 OUTPUT B ~2202 40V 16A 50/60Hz LINK B INPUT B stereo 21 600W 2.6.5 Low Pass Filter Low Pass Filter allows only frequencies below 80Hz or 125Hz without the use of external crossovers when driving subwoofers.
  • Page 11: Connect To Ac Mains

    Professional Power Amplifier 2 Setup 2.7 Connect to AC Mains 2.8 Startup Procedure Use the following procedure when first turning on your Connect your amplifier to the AC mains power source (po- amplifier: wer outlet) with the supplied AC power cable. First, co- nnect the IEC end of the cable to the IEC connector on 1.
  • Page 12: Operation

    Professional Power Amplifier 3 Operation 3.1 Precautions 4. WARNING: Never connect the output to a power supply, battery or power Your amplifier is protected from internal and external main. Electrical shock may result. faults, but you should still take the following precautions for optimum performance and safety: Tampering with the circuitry, or making unauthorized circuit changes may be hazardous and invalidates your...
  • Page 13: Front Panel Controls And Indicators

    Ch-A Power 3 Operation Ch-A Signal, Indicator Ch-B Signal, Clip& PROT Clip& PROT 3.2 Front Panel Controls and Indicators PROTECT PROTECT CLIP CLIP ZENITH 3000 SIGNAL SIGNAL ACTIVE ACTIVE CH A POWER CH B Ch-A Level Control Power Switch Ch-B Power...
  • Page 14: Advanced Features And Options

    Professional Power Amplifier 4 Specifications Minimum Guaranteed Power ZENITH 1800 ZENITH 2400 ZENITH 3000 1 kHz with 0.5% THD Stereo, 4 ohms (per ch.) 960W 1280W 1600W Stereo, 8 ohms (per ch.) 600W 800W 1000W Bridge mono, 8 ohms 1800W...
  • Page 15: Advanced Features And Options

    Professional Power Amplifier 4 Specifications Minimum Guaranteed Power Performance ZENITH 1800 ZENITH 2400 ZENITH 3000 Load Impedance Stereo 4-8 ohms 4-8 ohms 4-8 ohms Bridge Mono 8 ohms 8 ohms 8 ohms AC Line Voltage and Frequency Configurations Available ( 10%)