Finishing Around The Fireplace; Fireplace Facing - Montigo H38SVO-ST Installation And Maintenance Manual

Outdoor ventless see through residential gas fireplace
Table of Contents

Advertisement

Follow Figures 4,5 (wall installation) and Figure 3 (MIN size enclosure
for patio or other contemporary installation) to frame around the fireplace
chassis.
Note: ONLY Non-combustible materials must be used in construction
of the enclosure. (top, bottom and sides). Steel studs in combination
with concrete, rock, or stone finishing materials, are acceptable. See
Figures 3, 4 and 5.
Surrounding construction
( sides and top) must be
non-combustible materials,
metal studs,c oncrete board
and concrete ,b rick, or stone.
Backframe Min. 38"
both sides Typical
Figure 4.
Back framing dimensions. (without Optional surround)
24" Min.
Surrounding construction
(bottom, sides and top) must
be non-combustible materials,
metal studs,c oncrete board
and concrete,b rick, or stone.
Figure 5.
Framing dimensions (without Optional surround). Distance from
Existing Structures.
XG0817 - 140707.2
Installation
41"
41"
Backframe Min. 38"
both sides Typical

Fireplace Facing

When selecting the finish material for your fireplace, it is important to
remember the following: THE LOWER GAS CONTROL PANEL MUST
NOT BE OBSTRUCTED IN ANY WAY - to do so restricts the air supply
for the control compartments and heat exchanger it also prevents
access for servicing controls.
Decorative facing must not extend past the fireplace opening at all,
because it will interfere with the access to retainers for removal of
glass door.
42
39
36
33
30
27
24
21
18
15
12
9
6
3
1
Figure 6. Non-combustible mantles and facings.
H*38VO-ST Outdoor Gas Fireplace
Non combustible
Header
Non combustible
facing
Top of Fireplace
Page 7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hl38svo-st

Table of Contents