Section 9: Start-Up Sequence - Montigo H38DF ST Installation & Maintenance Manual

Indoor residential gas fireplace
Table of Contents

Advertisement

H*38DF ST Indoor Gas Fireplace

Section 9: Start-up Sequence

For Your Safety - READ BEFORE LIGHTING:
A. This appliance is equipped with an ignition system that lights the
pilot burner automatically. Do not attempt to light the pilot by hand.
B. BEFORE LIGHTING smell all around the appliance area for gas.
Be sure to smell next to the floor because some gas is heavier
than air and will settle on the floor.
What To Do If You Smell Gas:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbour's phone.
Follow the gas supplier's instructions.
1. STOP! Read the safety information above on this label.
2. Lift out the lower Horizontal access panel.
3. Push in gas control knob and turn clockwise
4. Wait five (5) minutes to clear out any gas. Smell for gas,
including near the floor. If you then smell gas, STOP! Follow
"B" in the safety information above on this label. If you don't
smell gas, go to the next step.
5. Locate pilot burner (See illustration at right.) and follow steps
below.
6. Turn knob on gas control counter clockwise
NOTE: Gas control knob cannot be turned from "PILOT" to "OFF"
unless knob is pushed in slightly. Do not force.
1. Turn off remote switch.
2. Lift out the lower Horizontal access panel.
Page 28
Operation
with American Flame Electronic Ignition
Standing (Continuous) Pilot Ignition
Lighting Instructions:
to "OFF."
to "PILOT."
To Turn Off Gas To Appliance:
WARNING
If the information in these instructions is not followed exactly, a fire or explosion may
result causing property damage, personal injury or death.
WARNING/ CAUTION: Hot while in operation. Do not touch.
Severe burns may result. Keep children, clothing, furniture,
gasoline and other liquids having flammable vapours away.
See installation and operating instructions accompanying this
appliance.
If you cannot reach your gas supplier, call the Fire Depart-
ment.
C. Use only your hand to push in or turn the gas control knob. Never
use tools. If the knob will not push in or turn by hand, don't try to
repair it, call a qualified service technician. Force or attempt to
repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system, and any
gas control which has been under water.
(SIT NOVA 820)
7. Push in gas control knob completely and hold. Light with Piezo
Igniter button. Continue to hold the control knob in for about
(1) minute after the pilot is lit. Release the knob and it will pop
back up. Pilot should remain lit. If it goes out repeat steps 3
through 8.
If knob does not pop up when released. Stop and immediately
call your service technician or gas supplier.
If the pilot will not stay lit after several tries, turn the gas control
knob to "OFF" and call your service technician or gas supplier.
8. Push in gas control knob and turn counter-clockwise
to "ON."
9. Replace the lower Horizontal access
panel.
10. Turn on remote switch to ignite fire.
3. Push in gas control knob slightly and turn
"Off". Do not force.
4. Replace the lower Horizontal access panel.
clockwise to
XG0207 - 150204.1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hl38df st

Table of Contents