Section 10: Start Up Sequence; Standing (Continuous) Pilot Ignition (Sit 820) - Montigo DIVINE H34DFN Installation & Maintenance Manual

Divine single sided indoor direct vent gas fireplace
Table of Contents

Advertisement

Section 10: Start up Sequence

A. This appliance is equipped with an ignition system that lights the pilot burner
automatically. Do not attempt to light the pilot by hand.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call the Fire Department.
1.
STOP! Read the safety information above on this label.
2.
Lift out the lower Horizontal access panel.
3.
Push in gas control knob and turn clockwise
on this label. If you don't smell gas, go to the next step.
5.
Locate pilot burner (See illustration at right.) and follow steps below.
6.
Turn knob on gas control counter clockwise
Gas control knob (Shown in PILOT position)
NOTE: Gas control knob cannot be turned from "PILOT"
to "OFF" unless knob is pushed in slightly. Do not
force.
2.
Lift out the lower Horizontal access panel.
XG0228 - 021419
with American Flame Electronic Ignition
to "OFF."
to "PILOT."
WARNING
If the information in these instructions is not followed exactly, a fire or explosion may
result causing property damage, personal injury or death.
WARNING/ CAUTION: Hot while in operation. Do not touch. Severe burns
may result. Keep children, clothing, furniture, gasoline and other liquids
See installation and operating instructions accompanying this appliance.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If
D. Do not use this appliance if any part has been under water. Immediately call
of the control system, and any gas control which has been under water.
Continue to hold the control knob in for about (1) minute after the pilot is
lit. Release the knob and it will pop back up. Pilot should remain lit. If it goes
out repeat steps 3 through 8.
If knob does not pop up when released. Stop and immediately call your
service technician or gas supplier.
If the pilot will not stay lit after several tries, turn the gas control knob to
"OFF" and call your service technician or gas supplier.
8.
Push in gas control knob and turn counter-clockwise
9.
Replace the lower Horizontal access panel.
3.
Push in gas control knob slightly and turn
force.
4.
Replace the lower Horizontal access panel.
Operation
to "ON."

Advertisement

Table of Contents
loading