Ac Receptacle Selection; Power Producing Circuits - Honda EM5000is Owner's Manual

Hide thumbs Also See for EM5000is:
Table of Contents

Advertisement

OPERATION

AC Receptacle Selection

The control panel, shown below, has a voltage selector switch and
four receptacles. Receptacle
powered terminals, 4A and 4B.
RECEPTACLE
1
VOLTAGE
SELECTOR
SWITCH

Power Producing Circuits

This generator is equipped with two power generating circuits. When
the voltage selector switch is in the 120V/240V position, each of the
two power producing circuits supplies power to specific receptacles.
When the voltage selector switch is in the 120V ONLY position, the
power producing circuits operate in parallel, sharing the total load
connected to terminal 4A and receptacles 1, 2, and 3.
POWER
CIRCUIT 1
POWER
CIRCUIT 2
36
4, the 240-volt receptacle, has two
RECEPTACLE
2
120 V/240 V
RECEPTACLE
120 V ONLY
POWER CIRCUIT 2
POWER CIRCUIT 1
RECEPTACLE
4
TERMINAL 4A
TERMINAL 4B
3