Perform one of the following:
4.
If the array controller has failed, remove the cache module
o
44) and battery pack from the failed array controller, and install the cache module and battery pack
on an array controller in the recovery server.
If the server has failed, remove the controller
o
"Full-length expansion
44), and battery pack from the failed server, and install the controller, cache module, and battery
pack in the recovery server.
Power up the recovery server. A 1759 POST message is displayed, stating that valid data was flushed
5.
from the cache. This data is now stored on the drives in the recovery server. You can now transfer the
drives (and controller, if one was used) to another server.

Heatsink

To remove the heatsink:
Power down the server (on page 26).
1.
Extend the server from the rack (on page 25).
2.
Remove the access panel
3.
Remove the PCI riser cage
4.
Remove the air baffle
5.
Open the heatsink retaining bracket, and then remove the heatsink.
6.
To replace the heatsink:
Clean the old thermal grease from the processor with the alcohol swab. Allow the alcohol to evaporate
1.
before continuing.
board" on page 43), cache module
("Access
panel" on page 30).
("PCI riser
cage" on page 38).
("Air
baffle" on page 39).
("Removing the cache
("Half-length expansion
("Removing the cache
Removal and replacement procedures 46