Cutting Unit Operating Problems - Toro Reelmaster 2000-D Service Manual

Hide thumbs Also See for Reelmaster 2000-D:
Table of Contents

Advertisement

Cutting Unit Operating Problems

Problem
Engine Continues to run (but should not) when the reel
engage switch is ON with no operator in the seat.
Cutting units run (but should not) when raised.
However, they shut off with the reel engage switch.
Cutting units shut off when raised. However, they do
not shut off with the reel engage switch.
Cutting units do not engage.
Cutting units do not engage in Backlap direction.
Reelmaster 2000–D
Possible Causes
Backlap switch is in the backlap position.
Backlap switch is faulty or out of adjustment.
Wiring to the mow/backlap circuit components is loose,
corroded, or damaged (see Wiring Schematics).
Seat switch is faulty, out of adjustment, or short
circuited.
Cutting deck position switch or circuit wiring is faulty or
out of adjustment.
Reel engage switch is faulty or short circuited.
Operator not present in seat.
Cutting units are not lowered.
System fuse (10 amp) is open.
Fuse block is faulty.
Seat switch is faulty or out of adjustment.
Wiring to mow/backlap circuit components is loose,
corroded, or damaged (see Wiring Schematics).
Reel engage switch is faulty.
Cutting unit interlock switch is faulty.
Cutting unit solenoid valve or coil on hydraulic manifold
is faulty.
Cutting units are not lowered.
Parking Brake is not engaged.
System fuse (10 amp) is open.
Fuse block is faulty.
Seat switch is faulty or out of adjustment.
Parking brake switch is faulty or out of adjustment.
Wiring to mow/backlap circuit components is loose,
corroded, or damaged (see Wiring Schematics).
Reel engage switch is faulty.
Backlap switch is faulty or out of adjustment.
Cutting unit interlock switch is faulty.
Cutting unit solenoid valve or coil on hydraulic manifold
is faulty.
Page 5 – 7
Electrical System

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents