Troubleshooting Gas Control (Honeywell Gas Valve) - Majestic DV360 Homeowner's Installation And Operating Manual

Direct vent gas fireplace
Table of Contents

Advertisement

DV360/580 Series Direct Vent Gas Fireplace
Remove Window Frame Assembly Before Service Work
START
Gas Supply On
YES
Pilot Lights With Piezo
Ignitor
YES
Pilot Stays Lit
YES
Pilot Lights Main Burner
YES
SYSTEM OK
34
Troubleshooting - Honeywell VS8421
CHECK
Supply Line Hooked Up
NO
Shutoff Valve Open
Lockout Has Engaged. Wait 60
Seconds And Try Again.
For Spark At Electrode While
Depressing Piezo
NO
1/8" Gap To Pilot Hood Needed.
All Wiring Connections
Replace Piezo Ignitor
For Air In The Lines
Thermopile Needs A Min.
325mv. Adjust Pilot Flame
Height.
All Wiring Connections
NO
Replace Thermopile
Thermocouple Needs A Min. Of
14mv
Valve Is Turned On
Wall Switch Is Not Turned On.
Watch For Grounded Wires!
NO
Thermopile Needs A Min. 325mv.
Plugged Burner Orifice
Defective Valve. Turn To Pilot,
Meter Should Read Greater Than
100mv. If Not, Replace.