Eb-1 Electrical Box; Electronic Gas Control Valve - Majestic 33BDVT Installation Instructions And Homeowner's Manual

Table of Contents

Advertisement

BDVT Series Direct Vent Gas Fireplace

EB-1 Electrical Box

The fireplace, when installed, must be
electrically connected and grounded in
accordance with local codes or, in the
absence of local codes, with the current
CSA C22.1 Canadian Electrical Code.
For USA installations follow local codes
and the national electrical code ANSI/
NFPA No. 70.
It is strongly suggested that the wiring
of the EB-1 Electrical Junction Box be
carried out by a licensed electrician.
Ensure that the power to the supply line
has been disconnected before com-
mencing this procedure.
The EB-1 Electrical junction box has been fitted standard
on this model to allow for the easy connection of an
optional fan kit.
To connect the EB-1 box to the house electrical supply
follow the steps below.
1. Unscrew retaining screw from EB-1 base plate (Fig.
8) and remove the EB-1 assembly from the appli-
ance.
2. Remove the front cover of the EB box.
3. Remove the plug socket assembly from the EB-1
box.
4. Feed the supply line in through the EB-1 opening in
the side of the appliance and then through the back
of the EB-1 assembly. (Fig. 8)
5. Connect the black wire of the power supply line to
the brass screw (polarized) of the socket assembly.
6. Connect the white wire of the power line to the
chrome screw of the socket assembly.
7. Connect the ground wire of the supply line to the
green screw of the socket assembly.
8. Refit the socket assembly back into the electrical
box and replace the cover plate. Secure the cable
with the clamp on the outside of the EB-1 base plate
and refit the EB-1 assembly to the unit with the
screw removed in step 1.
INSIDE
OUTSIDE
Fig. 8 EB-1 receptacle.
8
Electrical Box
Retaining Screw
FP580

Electronic Gas Control Valve

This appliance may be fitted with a Honeywell
ignition module.
Installation of the remote on/off switch on elec-
tronic ignition units.
1. Thread the wiring through the holes on the side
panels of the appliance. Take care not to cut the
wire or insulation on metal edges. Route the wire to
a conveniently located receptacle box.
2. Attach the wire to the ON/OFF switch and install the
switch into the receptacle box.
3. Connect the white wire from the wall switch to the
black wire from the transformer, using an approved
wire nut. Connect the black wire from the wall switch
to the black wire running from the #6 position of the
ignition module, also using an approved wire nut.
PILOT
MV
MV/VP PV
1
2
RED
ORANGE
ORANGE
WHITE
POWER CORD
W/FEMALE SPADE
120 VAC RTN
24 VAC HOT
WHITE
BLACK
GREEN
24 VAC RET
120 VAC HOT
40VA TRANSFORMER
Fig. 9 Honeywell Ignition Module.
HONEYWELL IGNITION MODULE
24V
GRD
24V
SENSE SPARK
3
5
6
8
9
GREEN
BLACK
HI
NOVA SIT 822 VALVE
BLUE
BLACK
BLACK
OFF
WHITE
YELLOW
WALL SWITCH
BLACK
WHITE
FP1225
10003358

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

39bdvt43bdvt36bdvt

Table of Contents