Transport
Boiler/stratification cylinder
Installation information
Recommended minimum
wall clearance
3062547_201507

7. Installation instructions

- The boiler and the stratification cylinder are transported, fully packaged, on a pallet
- A sack truck is a suitable means of transportation
- Position the sack truck behind the boiler or stratification cylinder, secure with a strap
and transport to the installation location
- Remove strap and packaging
- Remove the four fixing screws on the pallet
- Lift the boiler and/or stratification cylinder off the pallet
- Install the boiler or boiler plus DHW cylinder on a level
- Level the boiler and stratification cylinder horizontally using
Adjustable feet
- The boiler must only be installed in a room that is protected from frost.
NB
Drain the boiler, stratification cylinder and heating system if there is a risk
of frost when the system has been shut down.
- Boilers should not be installed in a room that is subject to aggressive vapours
NB
or in very dusty or highly humid conditions (workshops, washrooms, hobby
rooms, etc.).
- The combustion air must be free from halogenated hydrocarbons.
NB
- A surface temperature of 40 °C is not exceeded in the case of COB if
operated as intended. The respective national fire regulations are to be
observed in the case of installation in oil storage rooms.
The COB and TS are installed adjacent to the wall, which means that a clearance of
70 cm only needs to be observed at the front. When installing the boiler, you should
observe the recommended wall clearances in order to simplify assembly, maintenance
and servicing.
COB
70 cm
COB with
TS behind
surface which is substantial enough to carry its weight.
adjustable feet.
COB with
TS right
or left
70 cm
COB-40
minimum
room height
11