Leveling The Unit; Connecting Power; Battery Installation / Replacement - Montigo 30FID Traditional Installation & Maintenance Manual

Hide thumbs Also See for 30FID Traditional:
Table of Contents

Advertisement

I-Series Indoor Gas Fireplace

Leveling the Unit

This unit has 4 leveling screws, 2 located inside the rear of the
firebox and 2 located at the bottom front of the Rear Faceplate.
Once the unit is in position, you can use a Phillips screw driver or
Slotted screw drivers to adjust each leveling screw as required.
1). Remove burner, see section on burner removal and install
2). Rear leveling screw adjustment (Linear burner version shown)
Figure 4 Sec.8
3). Front leveling Screw adjustment (Linear burner version shown)
Figure 5 Sec.8
4). Reinstall the burner.
Page 34
Installation

Connecting Power

Please refer to the specification for power supply requirements.
This appliance is supplied with a Power Cord located on the right
side of the appliance. It can be connected directly to a standard
electrical outlet.

Battery Installation / Replacement

The 30FID-S uses 2 different sets of Batteries. The Control
Backup uses 4x AA batteries to continue operations during power
outages. The Remote Control uses 3x AAA Batteries for general
operation. The Control Backup Batteries should be changed on
a regular basis regardless of if they have been used or not so
that in the event of a power failure, you will continue to have an
operational heating appliance. To replace the Controller Backup
Batteries, remove the Front Faceplate and remove and re-install
new batteries into the Battery Holder located just above the main
Control Board.
Figure 6 Sec.8
Figure 7 Sec.8
XG00524-