Rear Vent Configuration with Horizontal Termination (no vertical rise)

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.
NG Applications
LP Applications
© Travis Industries
Installation
Optional 45 Degree Elbow
Vent with No 45° Elbow
915mm
Vent with 1 45° Elbow
915mm
Vent with No 45° Elbow
3 feet
915mm
0 feet
mm
Vent with 1 45° Elbow
3 feet
915mm
0 feet
mm
(for qualified installers only)
See the charts below to
determine maximum vent
3 feet
0 feet
mm
3 feet
0 feet
mm
14" Snorkel
(REQUIRED)
14" Snorkel
(REQUIRED)
4140926
Termination
• Exhaust Restrictor:
Remove the exhaust restrictor
and replace the screws.
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)
• Min. 4" (102mm) Horizontal Section
• Max.48" (1.2m) Horizontal Section(s)
• Exhaust Restrictor:
Remove the exhaust restrictor
and replace the screws.
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)
• Min. 4" (102mm) Horizontal Section
• Max. 24" (610mm) Horizontal Section(s)
• Exhaust Restrictor:
Remove the exhaust restrictor
and replace the screws.
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)
• Min. 4" (102mm) Horizontal Section
• Max.48" (1.2m) Horizontal Section(s)
• Exhaust Restrictor:
Remove the exhaust restrictor
and replace the screws.
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)
• Min. 4" (102mm) Horizontal Section
• Max. 24" (610mm) Horizontal Section(s)