Rear Vent Configuration With Horizontal Termination (No Vertical Rise) - Travis Industries 564 Cleanface Installation Manual

Gsr2 fireplace
Table of Contents

Advertisement

30

Rear Vent Configuration with Horizontal Termination (no vertical rise)

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.
Optional 45 Elbow
Vent with No 45 Elbow
3 feet
915mm
0 feet
Vent with 1 45 Elbow
3 feet
915mm
0 feet
Travis Industries
Installation
See the charts below to
determine maximum vent
mm
mm
(for qualified installers only)
Termination
-Exhaust Restrictor:
Remove the exhaust restrictor
and replace the screws.
-Intake Restrictor # 1 (stock)
-Diffuser Position # 1 (stock)
-Min. 4" (102mm) Horizontal Section
-Max.48" (1.2m) Horizontal Section(s)
-Exhaust Restrictor:
Remove the exhaust restrictor
and replace the screws.
-Intake Restrictor # 1 (stock)
-Diffuser Position # 1 (stock)
-Min. 4" (102mm) Horizontal Section
-Max. 24" (610mm) Horizontal Section(s)
4141209
100-01378