Hidden Hanger Bracket

Installation
The Hidden Overlay Hanger Brackets are used
for installations that do not require the standard
Backer Plate. They provide a means of attachment for the
Front Cast Iron Overlay assembly.
Left Bracket
225765
Right Bracket 225766
Upper Bracket 225767
M6 x 8 phillips truss head screws, 10
1. Attach each bracket using the 10 M6 x 8 phillips head
screws provided, as shown in fig. 56.
NOTE: Do not recess the unit into the fireplace
beyond the Upper Bracket. Mantle clearance data is
unavailable for a recessed installation.

Front Cast Iron Overlay

Assembly
The cast iron Overlay is shipped fully assembled, including
the integrated Safety Barrier Screen.
• Remove and discard the four plastic joint shims from
the front of the Brown Majolica frame assembly.
The Matte Black assembly does not ship with joint shims.
Installation
The overlay frame is heavy - assistance may be helpful.
Handle the enameled assembly carefully to avoid
inadvertent damage.
Simply engage the side mounting brackets with the steel
support tabs on either the Hanger Brackets or Backer
Plate, whichever is appropriate.
Mounting Brackets
Figure 57. Overlay mounting brackets.
139712_R00 GI 635 IPI Sept. 2015