925
Last Error
Code
926
Error Count
927
LCD Size
[8.1] Using Init TV
CAUTION:
When factory settings have been made, all user setting data, including the channel settings, are initialized.
(The adjustments done in the adjustment process mode are not initialized.) Keep this in mind when
initializing these settings.)
Item #
Item
001
Init TV
Not Applicable
The last error code recorded.
0x00 = DTV HANGUP
0x01 = POWER_ON_RESET
0x02 = SUPPLY_VOLTAGE_INDICATION_ERROR
0x04 = OUTPUT_VERTICAL_GUARD_ERROR
0x08 = XRAY_PROTECTION_ERROR
0x10 = PROTECTION_1_8V_SUPPLY_VOLTAGE_ERROR
Not Applicable
Number of times the set went into reset due to an error.
1 = LC-32WD1E
Sets the panel size of the TV. Set this setting after replacing the mainboard. This
setting must be set to make sure the right settings are loaded for this TV
1 = LC-32WT1E
(gamma table, etc.).
2 = LC-32WD1S
3 = LC-32WD1RU
4 = LC-37WD1E
4 = LC-37WT1E
5 = LC-37WD1S
6 = LC-37WD1RU
7 = LC-42WD1E
7 = LC-42WT1E
8 = LC-42WD1S
9 = LC-42WD1RU
Adjustment Conditions
See caution above.
Adjustment Procedure
1. Enter the adjustment process mode.
2. Go to this item. Press
The screen will go dark and the LEDs on the front of the TV
will alternate between cycling and all illuminated.
When finished, the On/Standby LED will illuminate GREEN
and the TV will be on.
CAUTION: Never turn the power off during initialization.
The following settings have been reset to the factory settings:
• User settings.
• Channel data (e.g., broadcast frequencies)
• Password data
5 - 10
.