ART COOL GALLERY INDOOR UNITS
Installation and Best Layout Practices
Wired Controller Connections
Figure 64:Wired Controller Connection on the Indoor Unit Terminal Block.
Indoor Unit Terminal Block
GND
1(L1 ) 2(L2)
To Outdoor Unit or Branch Distribution Unit
(Multi F MAX Systems Only)
Wired Controller Placement
Wired controllers include a sensor to detect room temperature. To maintain comfort
levels in the conditioned space, the wired controller must be installed in a location
away from direct sunlight, high humidity, and where it could be directly exposed to
cold air. Controller must be installed four (4) to five (5) feet above the floor where its
LED display can be read easily, in an area with good air circulation, and where it can
detect an average room temperature.
Do not install the wired controller near or in:
• Drafts or dead spots behind doors and in corners
• Hot or cold air from ducts
• Radiant heat from the sun or appliances
• Concealed pipes and chimneys
• An area where temperatures are uncontrolled, such as an outside wall
Hanging the Wired Controller
1. The controller wiring / cable can be installed in one of three direc-
tions: top, back, or on the right side. If top or right side installation
is desired, remove cable guide grooves on the controller, and
then position wiring / cable on applicable side.
2. Choose and mark the area of installation, and then screw the wall
plate into place (using the provided parts). Install the controller
wall plate to fit the electrical box if one is present. Ensure that no
gaps exist between the wall plate and the wall itself.
3. Arrange wiring / cables so as not to interfere with the controller
circuitry. Position the wired controller on the wall plate. Snap into
place by pressing the bottom part of the wired controller onto
the wall plate. Make sure that no gaps exist between the wired
controller and the wall plate on all sides.
4. To remove wired controller from the wall plate, insert a screw-
driver into the two holes at the bottom. Twist screwdriver to
release controller. Do not damage the controller components
when removing.
54 | ART COOL GALLERY™
CN-REMO
3
To Wired Controller
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
Figure 65:Proper Location for the Wired Controller.
TEM
P
roller
ot e
Rem
Cont
NO
Figure 66:Removing the Cable Guide Grooves.
Top
Back
Right
Side
Figure 67:Attaching the Wall Plate.
F
MULTI
F
MULTI
MAX
YES
TEMP
Remote Controlle r
NO
TEMP
Remote Controlle r
NO
4 to 5 feet
above the floor
Top
Figure 68:Installing / Removing
the Controller.
Installing the Controller
Wall
Removing the Controller
Wall
Right
Side
Wall
Wall