External Static Pressure / Acoustic Data - LG MULTI F Engineering Manual

Hide thumbs Also See for MULTI F:
Table of Contents

Advertisement

F
MULTI
F
MULTI
MAX
Table 58:Multi F Ceiling-Concealed Duct (High Static) External Static Pressure Setting Values Table.
Static Pressure (in. wg)
Model No. / Nominal Capacity
of Indoor Unit (Btu/h)
LMHN240HV
24,000
LMHN360HV
36,000
• To get the desired air flow and external static pressure combination, use the setting value from the table. Using a setting value other
than that listed in the table will not provide the desired combination.
• Table data is based at 230V. Air flow rate varies according to voltage fluctuation.
Figure 157: Sound Pressure Level Measurement Location.
DISCHARGE
DUCT
6.6 ft.
Figure 158: Sound Pressure Level Diagrams.
LMHN240HV
80
70
60
50
40
30
20
Approximate
Hearing
Threshold
10
63
125
250
500
1000
2000
Octave Band Center Frequency (Hz)
DUCT (HIGH STATIC) INDOOR UNITS
0.1
Airflow Rate / CFM
High
688
82
Mid
618
78
Low
530
73
High
1,130
-
Mid
953
-
Low
706
-
SUCTION
DUCT
3.3 ft.
80
70
NC-65
60
NC-60
NC-55
50
NC-50
NC-45
40
NC-40
NC-35
30
NC-30
NC-25
20
Approximate
NC-20
Hearing
Threshold
NC-15
10
4000
8000
63
125
Octave Band Center Frequency (Hz)
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.

External Static Pressure / Acoustic Data

0.16
0.23
0.31
0.39
Setting Value (in. wg)
92
103
113
122
89
99
110
119
86
96
107
116
124
133
140
148
112
122
130
137
97
107
117
125
• Measurements taken with no attenuation and units operating at full
load normal operating condition.
• Sound level will vary depending on a range of factors such as
construction (acoustic absorption coefficient) of particular area in
which the equipment is installed.
• Sound power levels are measured in dB(A)±3.
• Tested in anechoic chamber per ISO Standard 3745.
Table 59:Sound Pressure Levels (dB[A]).
Sound Pressure Levels (dB[A]) (Cooling and Heating)
Model No.
High Fan Speed
LMHN240HV
LMHN360HV
LMHN360HV
NC-65
NC-60
NC-55
NC-50
NC-45
NC-40
NC-35
NC-30
NC-25
NC-20
NC-15
250
500
1000
2000
4000
8000
0.47
0.55
0.62
0.70
131
140
147
128
137
144
125
134
141
154
160
-
145
152
-
133
141
-
Medium Fan
Low Fan Speed
Speed
37
36
44
42
DUCT (HIGH STATIC) | 117
0.78
154
160
151
157
148
154
-
-
-
-
-
-
35
40

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents