MAX
Controller Options
Ceiling-concealed duct (low static) indoor units include an LG-supplied wired controller
(AKB72955816)
, but other optional LG-supplied wired controllers are available (see
1
Controls and Options overview on pages 9 to 12 in this manual's Introduction section).
The wireless handheld controller (Model No. PQWRHQ0FDB) is also an optional
accessory with use of the wired controller.
• Operation Display Panel: Displays operation conditions.
• Temperature Control Button: Sets desired temperature.
• Fan Speed Button: Sets desired fan speed.
• On / Off Button: Turns system operation on and off.
• Mode Selection Check Button: Selects the operation mode: Cooling, Heating, Auto,
Dry (Dehumidification), or Fan.
Each function will display on the LED for about three (3) seconds when the power is first cycled on.
Simple Mode Controllers for the ceiling-concealed duct (low static) indoor units are also referenced by Model No. PQRCVCL0QW.
1
Wired Controller Connections
Controllers can connect to the indoor unit in one of two different
ways.
1. LG Wired Remote Extension Cable with Molex plug (PZCWRC1;
sold separately) that connects to the CN-REMO terminal on the
indoor unit PCB.
2. Field-supplied controller cable that connects to the indoor unit
terminal block (must be at least UL2547 or UL1007, 22 AWG,
two-core, one-shield core, at least FT-6 rated if local electric and
building codes require plenum cable usage).
When using field-supplied controller cable, make sure to connect
the yellow to yellow (communications wire), red to red (12V power
wire), and black to black (ground wire) terminals from the remote
controller to the indoor unit terminal blocks.
DUCT (LOW STATIC) INDOOR UNITS
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
Installation and Best Layout Practices
Wired Controller
Figure 145:AKB72955816
TEMP
Figure 146:PZCWRC1 LG Wired Remote Extension Cable.
Verify the connectors are properly inserted.
FAN
SPEED
TEMP
OPER
MODE
Figure 147:Wired Controller Connections on the Indoor Unit
Terminal Block.
CN-REMO
Indoor Unit Terminal Block
YL
RD BK
1(L) 2(N)
12V
Comm.
Power Ground
Wired Controller.
1
FA N
SPEED
OPER
MODE
C/BOX Cable (Plug type)
To Indoor Unit
CN-REMO
Terminal
Extension cable
GND
3
DUCT (LOW STATIC) | 107
Outd
Branch D
(Mu

Hide quick links: