Sharp Aquos LC-45GD6U Operation Manual page 96

Liquid crystal television
Hide thumbs Also See for Aquos LC-45GD6U:
Table of Contents

Advertisement

Appendix
PC Control of the TV
• When a program is set, the Display can be controlled from the PC using the RS-232C terminal.
The input signal (PC/AV) can be selected, the volume can be adjusted and various other adjustments and
settings can be made, enabling automatic programmed playing.
• Attach an RS-232C cable cross-type (commercially available) to the supplied Din/D-Sub RS-232C for the
connections .
• This operation system should be used by a person who is accustomed to using computers.
Communication conditions
Set the RS-232C communications settings on the PC to match the display's communications conditions.
The Display's communications settings are as follows:
9,600 bps
8 bits
None
1 bit
None
Communication procedure
Send the control commands from the PC via the RS-232C connector.
The display operates according to the received command and sends a response message to the PC.
Do not send multiple commands at the same time. Wait until the PC receives the OK response before sending
the next command.
Command format
Eight ASCII codes
+
CR
I
Command 4-digits
Command 4-digits:Command. The text of four characters.
Parameter 4-digits:Parameter 0 - 9, x, blank,
?
/~
Paramet~r
4-dlglts
Return code
Parameter
Input the parameter values, aligning left, and fill with blank(s) for the remainder. (Be sure that 4 values are input for the
parameter.)
When the input parameter is not within an adjustable range, "ERR" returns. (Refer to "Response code format".)
Any numerical value can replace the "x" on the table.
CITIIJ
~
~
~
~
When
"?"
is input for some commands, the present setting value responds.
CITID
@-95

Advertisement

Table of Contents
loading

Table of Contents