Quadra-Fire YOSEMITE-MBK Owner's Manual page 2

Yosemite non-catalytic, front/side load, wood heater
Hide thumbs Also See for YOSEMITE-MBK:
Table of Contents

Advertisement

Yosemite Wood Stove
H
earth & Home Technologies welcomes you to our tradition of
excellence! In choosing a Quadra-Fire appliance, you have our
assurance of commitment to quality, durability, and performance.
This commitment begins with our research of the market, including
'Voice of the Customer' contacts, ensuring we make products that
will satisfy your needs. Our Research and Development facility
then employs the world's most advanced technology to achieve
the optimum operation of our stoves, inserts and fi replaces. And
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction
LABEL IS LOCATED ON THE BACK OF THE STOVE
CAUTION:
Tested and
O-T L
Listed by
C
OMNI-Test Laboratories, Inc.
Report: #061-S-54-2
LISTED ROOM HEATER, SOLID FUEL TYPE. ALSO FOR USE IN MOBILE
"For Use with Solid Wood Fuel Only"
HOMES. (UM) 84-HUD .
PREVENT HOUSE FIRES
Install and use only in accordance with manufacturer's
installation and operating instructions. Contact local building or
fire officials about restrictions and installation inspections in
your area. Do not obstruct the space beneath heater.
WARNING - For Mobile Homes: Do not install in a sleeping
room. An outside combustion air inlet must be provided and
unrestricted while unit is in use. The structural integrity of the
mobile home floor, ceiling and walls must be maintained. The
stove needs to be properly grounded to the frame of the mobile
home. Components required for mobile home installation:
Outside Air Kit, Part Number 831-1780.
Refer to manufacturer's instructions and local codes for
precautions required for passing chimney through a
combustible wall or ceiling and maximum offsets.
Inspect and clean chimney frequently - Under Certain Conditions of
Use, Creosote Buildup May Occur Rapidly.
Do not connect this unit to a chimney serving another
appliance.
Optional Components: Optional Blower, Part 831-1701.
Electrical Rating: 115 VAC, 1.2 Amps, 60 Hz.
Route power cord away from unit. Do not route cord under or
in front of appliance.
DANGER: Risk of electrical shock. Disconnect power supply
before servicing.
Replace glass only with 5mm ceramic available from your dealer.
Do not use grate or elevate fire. Build wood fire directly on
firebrick.
Do not overfire - if heater or chimney connector glows, you are
overfiring.
Operate only with the fuel loading door closed. Open only to
add fuel to the fire.
FLOOR PROTECTION*:
Both fuel loading doors accessible
Floor
protector
must
be
non-combustible
material
or
equivalent, extending beneath
heater and to front/sides/rear as
Fuel loading doors
Front
indicated
on
the
diagram.
Exception: Non-combustible floor
8"
protections must extend beneath
(203mm)
the flue pipe when installed with
horizontal venting and extend 2
44-1/2
inches (51mm) beyond each side.
*In Canada: Must be minimum 18 inches (450mm) in front of both
Manufactured by:
fuel loading doors and 8 inches (200mm) on both sides and back.
2015 2016 2017
1445 North Highway,
Colville, WA 99114
DO NOT REMOVE THIS LABEL
www.quadrafire.com
Made in U.S.A.
Page 2
and Welcome to the Quadra-Fire Family
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN
BURNS. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE
NAMEPLATE AND INSTRUCTIONS.
Portland
Oregon USA
US
TESTED TO:
UL 1482, UL737, ULC
S627-00.
Six inch (6 inches) (152mm) diameter, minimum 24 MSG black or blued steel connector pipe, with a listed factory-built
SINGLE WALL:
UL103 HT Class "A" chimney, suitable for use with solid fuels, or a masonry chimney, and the referenced clearances.
Six inch (6 inches) (152mm) diameter, listed double wall air insulated connector pipe with listed factory-built UL103 HT
DOUBLE WALL:
Class "A" chimney, or a masonry chimney and the referenced clearances.
*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650 degree Factory-built chimneys.
Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or Security DL double wall connector pipe. Must be
MOBILE HOME:
equipped with a spark arrestor. Apply double wall clearances below when installing unit.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.
TOP VENT VERTICAL
A
B
Single Wall-USA
12.5(316) 9(229) 19.5(495) 25.5(648) 10(254) 16 (406) 14(356) 16(406) 18.5(470) 20.5(521) 59(1499) N/A
Single Wall-Canada
12.5(316) 9(229) 19.5(495) 27.5(669) 10(254) 18 (457) 14(356) 18(457) 18.5(470) 22.5(572) 59(1499) N/A
Double Wall- USA
10.5(267) 7(178) 19.5(495) 25.5(648) 10(254) 16(406) 7 (178) 16(406) 11.5(292) 20.5(521) 59(1499) N/A
Double Wall-Canada 1 0.5(267) 7(178) 19.5(495) 27.5(699) 10(254) 18(457) 7 (178) 18(457) 11.5(292) 22.5(572) 59(1499) N/A
HORIZONTAL WITH MINIMUM 2FT (609mm) VERTICAL OFF STOVE TOP
Single Wall-USA
13.5(343) 10(254) 19.5(495) 25.5(648) 10(254) 16 (406) N/A
Single Wall-Canada
13.5(343) 10(254) 19.5(495) 27.5(699) 10(254) 18 (457) N/A
Double Wall-USA
11.5(330) 8(203) 19.5(495) 25.5(648) 10(254) 16(406)
Double Wall-Canada 11.5(330) 8(203) 19.5(495) 27.5(699) 10(254) 18(457)
**NFPA MINIMUM CLEARANCE - NOT TESTED
Side fuel loading door locked shut
8"
(203mm)
Front Fuel
Side
36-11/16
"
loading door
(932mm)
36-11/16
"
Minimum
(932mm)
Minimum
Minimum 16"
8"
from
(406mm)
16"
from fuel
(203mm)
(406mm)
fuel loading
loading door
door
USA
USA
"
(1130mm)
Minimum
33"(838mm) Minimum
Jan.
Feb.
Mar. Apr.
May June
July Aug. Sept. Oct.
U.S. ENVIRONMENTAL PROTECTION AGENCY -
Certified to comply with 2015 particulate emission standards at 2.7 g/hr EPA Methods 28
of US and imported parts.
and 5G. Not approved for sale after May 15, 2020.
yet we are old-fashioned when it comes to craftsmanship. Each
unit is meticulously fabricated and gold and nickel surfaces are
hand-fi nished for lasting beauty and enjoyment. Our pledge to
quality is completed as each model undergoes a quality control
inspection.
We wish you and your family many years of enjoyment in the
warmth and comfort of your hearth appliance. Thank you for
choosing Quadra-Fire.
007175
R
YOSEMITE
VENT SPECIFICATIONS:
C1
C2*
D1
D2*
E1
E2*
F1
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
SEE MANUAL FOR OTHER CONFIGURATIONS
B
A
Non-fuel
C2
door side
C1
D2
D1
Fuel Door
side
Non-fuel
Fuel door
door side
This wood heater needs periodic inspection and repair for
Nov. Dec.
proper operation. Consult the owner's manual for further
information. It is against federal regulations to operate this
wood heater in a manner inconsistent with the operating
instructions in the owner's manual.
7004-187L
!
SERIAL NO.
Serial Number
Model Name
F2*
G
H
Testing Lab &
Report Number
N/A
59(1499) 18**
N/A
59(1499) 18**
N/A
59(1499) 18**
N/A
59(1499) 18**
H
G
F2
E2
side
Mfg. Date
7004-188J
R
October 13, 2015