Section 4: Installation Consideration - Quadra-Fire YOSEMITE-MBK Owner's Manual

Yosemite non-catalytic, front/side load, wood heater
Hide thumbs Also See for YOSEMITE-MBK:
Table of Contents

Advertisement

4
Installation Considerations
A. Hearth Protection Requirements
FLOOR PROTECTION: Floor protector must be non-
combustible material, extending beneath heater and to the
front, sides and rear as indicated. The fl oor must be non-
combustible or otherwise adequately protected from radiant
heat given off by the unit and from sparks and falling embers.
A layer of thin brick or ceramic tile over a combustible fl oor
is not suffi cient.
In US installations, it is necessary to install a fl oor protec-
tor a minimum of 16 inches (406mm) in front of glass and 8
inches (203mm) to both sides of the fuel loading door. Open
the door and measure 8 inches (203mm) from the side edge
of the opening in the face of the appliance. *See exception.
Fuel door opening
8 in.
Non-fuel
door side
35 1/4 in.
minimum
Figure 11.1
IF SIDE FUEL LOADING DOOR IS NOT USED:
- It must remain in the locked position at all times
- Use clearances for non-fuel door side for both sides
October 13, 2015
R
36 in.
minimum
Minimum 16 in.
(406mm) from
fuel loading door
USA
In Canada, similar fl oor protection must be provided 18
inches (457mm) in front and 8 inches (203mm) from the
sides and rear of the stove. *See exception.
*EXCEPTION: Non-combustible fl oor protections must
extend beneath the fl ue pipe when installed with horizontal
venting and extend 2 inches (51mm) beyond each side.
See Figure 11.2.
Fire Risk.
• Hearth pads must be installed exactly as
specified.
High temperatures or hot embers may ignite
concealed combustibles.
8 in.
Fuel door opening
8 in.
Non-fuel
door side
Figure 11.2
NOTE: Corner hearth pad dimensions are based off of 18" min. clear-
ance for single wall pipe, 6" min. for double wall pipe, OR unit tested
safety clearances to combustibles whichever is greater.
7004-187L
Yosemite Wood Stove
WARNING
1187 mm
(46-3/4 in.)
minimum
Minimum 450mm
(18 in.) from each
fuel loading door
CANADA
1264mm
(35 1/4 in.)
minimum
Must extend 2 in.
(51mm) beyond
each side of pipe
(shaded area)
Page 11