Specification
operating
temperature
Expanded
Operating
Temperature
Restrictions

Environmental specifications

NOTE: For additional information about environmental measurements for specific system
configurations, see Dell.com/environmental_datasheets.
Temperature
Specifications
Storage
–40°C to 65°C (–40°F to 149°F)
temperature limits
Maximum
20°C/h (36°F/h)
temperature
gradient (operating
and storage)
Relative humidity
Specifications
Storage
5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-
condensing at all times.
Temperature
Specifications
(continuous
operation)
Temperature
10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
ranges (for altitude
less than 950 m or
3117 ft)
Fresh air
For information on fresh air, see
Humidity
10% to 80% Relative Humidity with 26°C (78.8°F) maximum dew point.
percentage range
Maximum vibration Specifications
Operating
0.26 G
Do not perform a cold startup below 5°C.
The operating temperature specified is for a maximum altitude of 3048 m
(10,000 ft).
PCIe SSD and 1.8 inch SSDs are not supported.
GPU is not supported.
145 W and Workstation CPU (160 W) processors are not supported.
Two power supply units are required and one power supply unit failure is not
supported.
Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W
are not supported.
NOTE: For information on restrictions, see
at 5 Hz to 350 Hz (all operation orientations).
rms
Standard operating
Expanded Operating
Temperature.