REMOVING THE HOOD EXHAUST FAN MOTOR

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug microwave oven or disconnect
power.
2.
Remove the microwave oven from its
mounting location (see page 2-4 for the
procedure and do procedure in reverse).
3.
Remove the cabinet from the oven (see
page 4-4 for the procedure).
Hood Exhaust Fan Motor
4.
Remove the two hood exhaust fan motor
screws from the rear panel.
5.
Unlatch and disconnect the hood exhaust
fan motor wire connector from the oven.
Wire Connector
Hood Exhaust Fan Motor Screws
6.
Lift the hood exhaust fan motor out of the
oven and remove it.
4-8