Connecting To A Gate Operator; Figure 5: Video Camera Wiring; Figure 6: Gate Operator Wiring - Chamberlain LiftMaster Q Installation Manual

Liftmaster q access keypad
Table of Contents

Advertisement

The display and keypad are backlit at a low level to conserve power
when no one is using the device. This low level is sufficient to read the
display at night. As soon as a customer touches a key, the display
comes on to full brightness, making it easier to read the instructions.
The messages described instruct the customer to "Press * to begin". The
customer starts the code entry by pressing the * key. The keypad will go
through all of the security checks described in the previous section
before allowing the customer to enter his or her code. If all of the security
checks pass then the key[ad will show the following message asking the
customer to enter his or her code.
* PLEASE ENTER *
YOUR ACCESS CODE
PRESS # WHEN DONE
The customer enters their access code and presses the # key. The keypad
sends the code to the controller and waits for a response. The message on
the display will change to the following while waiting for a response.
* PLEASE WAIT *
VERIFYING ACCESS
When the keypad receives a response from the controller it will show the
response message in the display. The messages that can be received
from the controller vary depending on the type of response. The various
response messages are shown in the Access Response Messages
section.
28

Figure 5: Video Camera Wiring

Connecting to a Gate Operator

Most gate operators use a single dry contact to trigger the gate to open.
See
Figure 6 for details on connecting a gate operator to the Q Access
Keypad.

Figure 6: Gate Operator Wiring

The Q Access Keypad is equipped with two Form C relays for use with
gate operators. Both relays are connected to the removable terminal