4. The DIMM error LEDs, microprocessor error LEDs, and VRM error LEDs turn
Note: See "System" on page 116 to determine which components should be replaced by a field service technician.
Diagnostics panel LED
All LEDs off
(Check System Error Log for error
condition, then clear System Error
Log when the problem is found.)
FAN LED on (The LED next to the
failing fan is on.)
MEMORY LED on (The LED next
to the failing DIMM is on.)
CPU LED on (The LED next to the
failing CPU is on.)
PCI BUS LED on
VRM LED on (The LED next to the
failing VRM is on.)
DASD LED on (The LED located
next to the drive bay that the failing
drive is installed in is lit. Check the
amber drive LED for the failing hard
drive.)
ISMP LED (Integrated System
Management detects an internal
error.)
POWER SUPPLY 1 LED on
POWER SUPPLY 2 LED on
NONREDUNDANT LED on
NMI LED on
off when the system is turned off.
FRU/action
1. System Error Log is 75% full; clear the log.
2. PFA alert; check log for failure; clear PFA alert; remove ac power for at
least 20 seconds, reconnect, then turn on the system.
3. Run light path diagnostics.
1. Failing fan.
2. System board
1. Failing DIMM.
2. System board
1. Run the Configuration/Setup Utility program to verify that all
microprocessors have identical cache sizes, dock speeds and clock
frequencies.
2. Microprocessor 1 or 2.
3. System board.
1. Remove all PCI adapters from slots on affected bus (see
"System-board LED locations" on page 49 for bus information, see
"Working with adapters" on page 51).
2. System board.
1. Voltage regulator module indicated by the lit VRM LED.
2. Microprocessor indicated by the microprocessor LED.
1. Be sure the fans are operating correctly and the airflow is good.
2. If installed, reseat I2C cable between DASD backplane and DASD I2C on
the system board (J10).
3. Failing drive. SCSI channel A has failed. (This is the SCSI channel for the
hot-swap hard disk drives).
4. DASD backplane.
1. .Update ISMP firmware with latest level code. Unplug AC power from
the server for at least 30 seconds, and then retry.
2. System board.
1. Check the dc good LED on power supply 1. If it is off, replace power
supply 1.
2. Power cage assembly.
1. Check the dc good LED on power supply 2. If it is off, replace power
supply 2.
2. Power cage assembly.
1. Check the PS1 and PS2 LEDs and replace any indicated power supply.
2. Install an additional power supply or remove optional devices from the
server.
1. Restart the server.
2. Check the System Error Log.