WIRING DIAGRAM:

IS-SS-RA-R
NO
COM
NC
N/O Dry Contact
24V AC/DC 500mA
RELAY BOARD WIRING AND SETTINGS:
Relay 1 Output
N/O, COM, N/C
Relay 2 Output
N/O, COM, N/C
2-pin connector

SPECIFICATIONS:

Terminations:
Relay rating:
Operating Temp:
Wiring Distance:
Dimensions:
w/SBX-ISDVFRA:
Aiphone Corporation
1700 130th AVE NE * Bellevue, WA 98005
Ph: (800) 692-0200 * Fax: (425) 455-0071
tech@aiphone.com
IS-MV
CAT-5e
OFF ON
NO
C
NC
NO
C
NC
Board on back of unit
See wiring below
Configuration Switch
See Settings to right
**Relay 2 External Reset
Connect to N/O dry switch
RJ45 jack for audio
Screw terminals for door release and relay outputs
24V AC/DC 500mA on Door station, 24V AC/DC 1.0A on relay board
14° ~ 140°F / -10° ~ 60°C
980' with Cat-5e/6 cable
11-3/4" H x 7" W
11-11/16" H x 7-1/16" W x 2-13/16" D (top), 1-13/16" D (bottom)
FCC WARNING:
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may cause undesired operation.
For proper regulatory compliance, the drain wire should be disconnected at the power
supply end of the cable.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
TOLL FREE TECHNICAL SUPPORT:
CAT-5e
* IS-SS-RA-R can connect to any
control unit (IS-CCU, IS-SCU, IS-RCU)
Station must be programmed as an
audio only station.
Default Configuration when shipped
Relay 1 triggers on normal call, emergency call, and communication. Relay 1 remains on during communication.
Relay 2 triggers on emergency call and remains on during communication.
Trigger Source
RY1 Triggered?
Normal Call
Emergency Call
Talking
Door Release
Optional Configuration
Relay 1 triggers on normal call, emergency call, and communication. Relay 1 remains on during communication.
Relay 2 triggers on an emergency call and remains on during communication. Relay 2 requires reset.
Trigger Source
RY1 Triggered?
Normal Call
Emergency Call
Talking
Door Release
Contact Technical Support if additional switch configurations
are required.
(800) 692-0200
E-MAIL: tech@aiphone.com
IS-CCU
*
RY1 Remains ON
RY2 Triggered?
During Talking?
YES
YES
NO
YES
YES
YES
YES
YES
NO
NO
N/A
NO
RY1 Remains ON
RY2 Triggered?
During Talking?
YES
YES
NO
YES
YES
YES
YES
YES
NO
NO
N/A
NO
IS-PU-UL
RY2 Remains ON
RY2 Requires
During Talking?
Reset?
N/A
N/A
YES
NO
N/A
N/A
N/A
N/A
RY2 Remains ON
RY2 Requires
During Talking?
Reset?
N/A
N/A
YES
YES**
N/A
N/A
N/A
N/A
Pg. 2
IS-SS-RA-R Instr.
0413JD