WIRING DIAGRAM:
IX-DVF-4
IX-DVF-4
7"
SPECIFICATIONS:
Camera unit:
Min. illumination:
Terminations:
Operating Temp:
Wiring Distance:
Dimensions:
w/SBX-IDVFRA:
FCC WARNING:
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may cause undesired operation.
•
For proper regulatory compliance, the drain wire should be disconnected at the power supply end of the cable.
•
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the
equipment.
Programming
This programming guide will cover how to program an IX-DVF-4 door station and four IX-MV7 master
stations. The call buttons on the IX-DVF-4 are wired to the first 4 contact inputs on the station for placing
selective calls. The door station and the associated IX-MV7 master stations will need to be programmed
using IX Support Tool.
IX-DVF-4
Cat-5e / Cat-6
Button Pattern
1
2
3
4
1/16" 2-3/8"
7"
1/3" color CMOS 1.2 megapixal
5 Lux
RJ45
-40° ~ 140°F / -40° ~ 60°C
328' with CAT-5e/6 cable to switch
11-¾" H x 7" W
11-
⁄
" H x 7" W x 3-
⁄
11
5
16
PoE Switch
1/16" 2-3/8"
" D (top), 2-
⁄
" D (bottom)
5
16
16
IX-MV7
IX-MV7
IX-MV7
IX-MV7
Pg. 2