1. STOP! Read the safety information above on this label.
2. Remove the lower Horizontal access panel.
3. Turn "ON" manual "ON/OFF" switch located below the horizontal
access panel (if available).
4. Turn Incoming gas valve to the ON" position.
5. Wait 5 minutes to clear out any gas. If you smell gas, STOP! Fol-
low "B" in the safety information above on this label. If you don't
smell gas, go to the next step.
Stepper Motor
SW1
LED1
LED2
SW1 = Programing Button
LED1 = Red Diagnostic Light
LED2 = Amber Programing Remote Control Light
Typical Control Module shown
1� Turn off fireplace using wall switch or remote control.
2� Remove the lower Horizontal access panel.
XG0816 - 150204.1
Operation
SIT Proflame 2 Electronic Ignition
Lighting Instructions:
Main ON/OFF Switch
Main Harness
Sensor
Igniter
3.15A Fuse
Power
To Turn Off Gas To Appliance:
H*38DF PFC Peninsula Gas Fireplace
6. Turn fireplace "ON" using wall switch or remote control.
7. If the Fireplace does not light, the System will cycle through two
trials, (one minute audible clicking, thirty seconds of silence, and
then another one minute of audible clicking). If the system locks
out due to inadequate gas flow, refer to "Troubleshooting" in
instruction guide.
8. After completion of the information in the Troubleshooting section,
Repeat step 5.
9. If the system will not function correctly, follow the instructions "To
Turn Off Gas To Appliance" and call your service technician or gas
supplier.
Manifold Pressure
Test Connection
Inlet Pressure
Test Connection
Gas Valve
3� Turn the incoming gas control valve to "Off".
4� Replace the lower Horizontal access panel.
Hi Lo Adjustment
Pilot Adjustment Screw