5.2.5

Resetting the Maintenance Timer

Model RESV (RDC2):
1. From the Overview menu, step down to the Genset
Run Time menu.
2. Press the Select button and then step down to the
Next Maintenance screen.
3. Press the Select button.
4. Press the Up arrow button so that "Reset Maint
Timer? Yes" is displayed.
5. Press the Select button. After about two minutes,
the new maintenance interval and date are
displayed.
Model RESVL (DC2):
1. Press and hold the OFF and AUTO buttons
together until Maintenance Timer Reset is
displayed.
2. Release the OFF and AUTO buttons.

5.3 Spark Plugs

WARNING
Accidental starting.
Can cause severe injury or death.
Disconnect the battery cables before
working
on
Remove the negative (--) lead first
when disconnecting the battery.
Reconnect the negative (--) lead last
when reconnecting the battery.
Disabling the generator set.
cause severe injury or death.
generator set or equipment connected to the set, disable the
generator set as follows: (1) Press the generator set off/reset
button to shut down the generator set. (2) Disconnect the
power to the battery charger, if equipped. (3) Remove the
battery cables, negative (--) lead first. Reconnect the negative
(--) lead last when reconnecting the battery. Follow these
precautions to prevent the starting of the generator set by the
remote start/stop switch.
Reset the spark plug gap or replace the plugs with new
plugs as necessary.
1. Clean the area around the base of the spark plug to
keep dirt and debris out of the engine.
64
Section 5 Scheduled Maintenance
the
generator
set.
Accidental starting can
Before working on the
2. Remove the spark plug and check its condition.
Replace the spark plug if it is worn or if its reuse is
questionable.
3. Check the spark plug gap using a wire feeler
gauge. See Figure 5-3 for the recommended spark
plug gap. Adjust the gap by carefully bending the
ground electrode. See Figure 5-4 and Figure 5-5.
4. For easy removal, apply a light coating of anti-seize
lubricant to the cleaned spark plug threads. Wipe
away any excess compound.
5. Reinstall the spark plug into the cylinder head.
Torque
the
spark
(18--22 ft. lb.)
Generator Set Model
8/10/12RESV/RESVL
Figure 5-3 Spark Plug Gap
Figure 5-4 Checking the Spark Plug Gap
Figure 5-5 Adjusting the Spark Plug Gap
plug
to
24.4--29.8 Nm
Spark Plug Gap
0.508 mm (0.020 in.)